SAE International A New Piston Insulation Concept for Heavy-Duty Diesel Engines to Reduce Heat Loss from the Wall 2017-24-0161

Description
To reduce heat transfer between hot gas and cavity wall, thin Zirconia (ZrO 2 ) layer (0.5mm) on the cavity surface of a forged steel piston was firstly formed by thermal spray coating aiming higher surface temperature swing precisely synchronized with flame temperature near the wall resulting in the reduction of temperature difference. However, no apparent difference in the heat loss was analyzed. To find out the reason why the heat loss was not so improved, direct observation of flame impingement to the cavity wall was carried out with the top view visualization technique, for which one of the exhaust valves was modified to a sapphire window. Local flame behavior very close to the wall was compared by macrophotography. Numerical analysis by utilizing a three-dimensional simulation was also carried out to investigate the effect of several parameters on the heat transfer coefficient. From the observation of wall impinged flame, it was revealed that a kind of thermal boundary layer with Zirconia coating was thinner than the baseline, which could be resulted in the increase in heat transfer coefficient. Furthermore, the numerical simulation results suggested that higher wall surface temperature swing with Zirconia coating is not the main cause of thinner boundary layer, but surface roughness and/or porous structure is. To confirm the hypothesis, new pistons with different insulating structures were then experimented. Even though the heat loss was not so improved because of the limited area of insulation, the potential for BTE improvement was confirmed.
Description
To reduce heat transfer between hot gas and cavity wall, thin Zirconia (ZrO 2 ) layer (0.5mm) on the cavity surface of a forged steel piston was firstly formed by thermal spray coating aiming higher surface temperature swing precisely synchronized with flame temperature near the wall resulting in the reduction of temperature difference. However, no apparent difference in the heat loss was analyzed. To find out the reason why the heat loss was not so improved, direct observation of flame impingement to the cavity wall was carried out with the top view visualization technique, for which one of the exhaust valves was modified to a sapphire window. Local flame behavior very close to the wall was compared by macrophotography. Numerical analysis by utilizing a three-dimensional simulation was also carried out to investigate the effect of several parameters on the heat transfer coefficient. From the observation of wall impinged flame, it was revealed that a kind of thermal boundary layer with Zirconia coating was thinner than the baseline, which could be resulted in the increase in heat transfer coefficient. Furthermore, the numerical simulation results suggested that higher wall surface temperature swing with Zirconia coating is not the main cause of thinner boundary layer, but surface roughness and/or porous structure is. To confirm the hypothesis, new pistons with different insulating structures were then experimented. Even though the heat loss was not so improved because of the limited area of insulation, the potential for BTE improvement was confirmed.

Suppliers

Company
Product
Description
Supplier Links
A New Piston Insulation Concept for Heavy-Duty Diesel Engines to Reduce Heat Loss from the Wall - 2017-24-0161 - SAE International
Warrendale, PA, United States
A New Piston Insulation Concept for Heavy-Duty Diesel Engines to Reduce Heat Loss from the Wall
2017-24-0161
A New Piston Insulation Concept for Heavy-Duty Diesel Engines to Reduce Heat Loss from the Wall 2017-24-0161
To reduce heat transfer between hot gas and cavity wall, thin Zirconia (ZrO 2 ) layer (0.5mm) on the cavity surface of a forged steel piston was firstly formed by thermal spray coating aiming higher surface temperature swing precisely synchronized with flame temperature near the wall resulting in the reduction of temperature difference. However, no apparent difference in the heat loss was analyzed. To find out the reason why the heat loss was not so improved, direct observation of flame impingement to the cavity wall was carried out with the top view visualization technique, for which one of the exhaust valves was modified to a sapphire window. Local flame behavior very close to the wall was compared by macrophotography. Numerical analysis by utilizing a three-dimensional simulation was also carried out to investigate the effect of several parameters on the heat transfer coefficient. From the observation of wall impinged flame, it was revealed that a kind of thermal boundary layer with Zirconia coating was thinner than the baseline, which could be resulted in the increase in heat transfer coefficient. Furthermore, the numerical simulation results suggested that higher wall surface temperature swing with Zirconia coating is not the main cause of thinner boundary layer, but surface roughness and/or porous structure is. To confirm the hypothesis, new pistons with different insulating structures were then experimented. Even though the heat loss was not so improved because of the limited area of insulation, the potential for BTE improvement was confirmed.

To reduce heat transfer between hot gas and cavity wall, thin Zirconia (ZrO 2 ) layer (0.5mm) on the cavity surface of a forged steel piston was firstly formed by thermal spray coating aiming higher surface temperature swing precisely synchronized with flame temperature near the wall resulting in the reduction of temperature difference. However, no apparent difference in the heat loss was analyzed. To find out the reason why the heat loss was not so improved, direct observation of flame impingement to the cavity wall was carried out with the top view visualization technique, for which one of the exhaust valves was modified to a sapphire window. Local flame behavior very close to the wall was compared by macrophotography. Numerical analysis by utilizing a three-dimensional simulation was also carried out to investigate the effect of several parameters on the heat transfer coefficient. From the observation of wall impinged flame, it was revealed that a kind of thermal boundary layer with Zirconia coating was thinner than the baseline, which could be resulted in the increase in heat transfer coefficient. Furthermore, the numerical simulation results suggested that higher wall surface temperature swing with Zirconia coating is not the main cause of thinner boundary layer, but surface roughness and/or porous structure is. To confirm the hypothesis, new pistons with different insulating structures were then experimented. Even though the heat loss was not so improved because of the limited area of insulation, the potential for BTE improvement was confirmed.

Supplier's Site

Technical Specifications

  SAE International
Product Category Standards and Technical Documents
Product Number 2017-24-0161
Product Name A New Piston Insulation Concept for Heavy-Duty Diesel Engines to Reduce Heat Loss from the Wall
Unlock Full Specs
to access all available technical data