SAE International Determination of Forming Limit and Fracture Limit Curves Using Digital Image Correlation 2014-01-0982

Description
Forming limit curve (FLC) and fracture forming limit curve (FFLC) are valuable tools for failure prediction in forming simulation and die try-out in press shops. In this paper, methods are presented to determine FLC and FFLC for sheets of advanced high strength steels (AHSS) using digital image correlation (DIC). Dome tests were conducted on AHSS specimens using DIC system for strain measurement. For generating FLCs, two approaches are introduced to determine the onset of localized necking by analyzing the strain history at critical locations, one of which has been implemented into the commercial DIC software Vic-3D (Correlated Solution inc.). For determination of FFLC, a method for measuring fracture strains based on the strain path evolution is presented. The measured FLCs for several AHSS were compared to the FLCs using ISO 12004-2, and conventional North American experimental measurements and empirical equations. The results of comparison revealed that FLCs using DIC are in good correlation with other existing data, thus validating the presented methodologies.
Description
Forming limit curve (FLC) and fracture forming limit curve (FFLC) are valuable tools for failure prediction in forming simulation and die try-out in press shops. In this paper, methods are presented to determine FLC and FFLC for sheets of advanced high strength steels (AHSS) using digital image correlation (DIC). Dome tests were conducted on AHSS specimens using DIC system for strain measurement. For generating FLCs, two approaches are introduced to determine the onset of localized necking by analyzing the strain history at critical locations, one of which has been implemented into the commercial DIC software Vic-3D (Correlated Solution inc.). For determination of FFLC, a method for measuring fracture strains based on the strain path evolution is presented. The measured FLCs for several AHSS were compared to the FLCs using ISO 12004-2, and conventional North American experimental measurements and empirical equations. The results of comparison revealed that FLCs using DIC are in good correlation with other existing data, thus validating the presented methodologies.

Suppliers

Company
Product
Description
Supplier Links
Determination of Forming Limit and Fracture Limit Curves Using Digital Image Correlation - 2014-01-0982 - SAE International
Warrendale, PA, United States
Determination of Forming Limit and Fracture Limit Curves Using Digital Image Correlation
2014-01-0982
Determination of Forming Limit and Fracture Limit Curves Using Digital Image Correlation 2014-01-0982
Forming limit curve (FLC) and fracture forming limit curve (FFLC) are valuable tools for failure prediction in forming simulation and die try-out in press shops. In this paper, methods are presented to determine FLC and FFLC for sheets of advanced high strength steels (AHSS) using digital image correlation (DIC). Dome tests were conducted on AHSS specimens using DIC system for strain measurement. For generating FLCs, two approaches are introduced to determine the onset of localized necking by analyzing the strain history at critical locations, one of which has been implemented into the commercial DIC software Vic-3D (Correlated Solution inc.). For determination of FFLC, a method for measuring fracture strains based on the strain path evolution is presented. The measured FLCs for several AHSS were compared to the FLCs using ISO 12004-2, and conventional North American experimental measurements and empirical equations. The results of comparison revealed that FLCs using DIC are in good correlation with other existing data, thus validating the presented methodologies.

Forming limit curve (FLC) and fracture forming limit curve (FFLC) are valuable tools for failure prediction in forming simulation and die try-out in press shops. In this paper, methods are presented to determine FLC and FFLC for sheets of advanced high strength steels (AHSS) using digital image correlation (DIC). Dome tests were conducted on AHSS specimens using DIC system for strain measurement. For generating FLCs, two approaches are introduced to determine the onset of localized necking by analyzing the strain history at critical locations, one of which has been implemented into the commercial DIC software Vic-3D (Correlated Solution inc.). For determination of FFLC, a method for measuring fracture strains based on the strain path evolution is presented. The measured FLCs for several AHSS were compared to the FLCs using ISO 12004-2, and conventional North American experimental measurements and empirical equations. The results of comparison revealed that FLCs using DIC are in good correlation with other existing data, thus validating the presented methodologies.

Supplier's Site

Technical Specifications

  SAE International
Product Category Standards and Technical Documents
Product Number 2014-01-0982
Product Name Determination of Forming Limit and Fracture Limit Curves Using Digital Image Correlation
Unlock Full Specs
to access all available technical data

Similar Products