SAE International Factors Influencing Contact Life and Failure Mode in Compact PCB Power Relays 2009-01-0558

Description
Compact PCB power relays were tested in repetitious on/off operations to define their reliability through a quantitative analysis of failure cycles and an investigation of relay property changes and contact erosion forms. Operation voltage was 14 V and relay temperature was 120 °C. Ten relays were used in each of two types of load test. First failure cycles were found to be high enough for practical use, 2.2 million in the lamp load (11 A) test and 7.5 million in the test using an integrated load (10 A) comprised of engine control components. Failure mode of all relays in the lamp load test revealed contact welding, while those in the integrated load test revealed significant contact resistance due to excess erosion. Wide differences between them in contact life cycle distribution and failure mode were found to be clearly distinguishable from load current characteristics.
Description
Compact PCB power relays were tested in repetitious on/off operations to define their reliability through a quantitative analysis of failure cycles and an investigation of relay property changes and contact erosion forms. Operation voltage was 14 V and relay temperature was 120 °C. Ten relays were used in each of two types of load test. First failure cycles were found to be high enough for practical use, 2.2 million in the lamp load (11 A) test and 7.5 million in the test using an integrated load (10 A) comprised of engine control components. Failure mode of all relays in the lamp load test revealed contact welding, while those in the integrated load test revealed significant contact resistance due to excess erosion. Wide differences between them in contact life cycle distribution and failure mode were found to be clearly distinguishable from load current characteristics.

Suppliers

Company
Product
Description
Supplier Links
Factors Influencing Contact Life and Failure Mode in Compact PCB Power Relays - 2009-01-0558 - SAE International
Warrendale, PA, United States
Factors Influencing Contact Life and Failure Mode in Compact PCB Power Relays
2009-01-0558
Factors Influencing Contact Life and Failure Mode in Compact PCB Power Relays 2009-01-0558
Compact PCB power relays were tested in repetitious on/off operations to define their reliability through a quantitative analysis of failure cycles and an investigation of relay property changes and contact erosion forms. Operation voltage was 14 V and relay temperature was 120 °C. Ten relays were used in each of two types of load test. First failure cycles were found to be high enough for practical use, 2.2 million in the lamp load (11 A) test and 7.5 million in the test using an integrated load (10 A) comprised of engine control components. Failure mode of all relays in the lamp load test revealed contact welding, while those in the integrated load test revealed significant contact resistance due to excess erosion. Wide differences between them in contact life cycle distribution and failure mode were found to be clearly distinguishable from load current characteristics.

Compact PCB power relays were tested in repetitious on/off operations to define their reliability through a quantitative analysis of failure cycles and an investigation of relay property changes and contact erosion forms. Operation voltage was 14 V and relay temperature was 120 °C. Ten relays were used in each of two types of load test. First failure cycles were found to be high enough for practical use, 2.2 million in the lamp load (11 A) test and 7.5 million in the test using an integrated load (10 A) comprised of engine control components. Failure mode of all relays in the lamp load test revealed contact welding, while those in the integrated load test revealed significant contact resistance due to excess erosion. Wide differences between them in contact life cycle distribution and failure mode were found to be clearly distinguishable from load current characteristics.

Supplier's Site

Technical Specifications

  SAE International
Product Category Standards and Technical Documents
Product Number 2009-01-0558
Product Name Factors Influencing Contact Life and Failure Mode in Compact PCB Power Relays
Unlock Full Specs
to access all available technical data

Similar Products