SAE International Multiple Regression Analysis of OSC Characteristics under Transient TWC Conditions 2008-01-0713

Description
Three Way Catalysts (TWC) contain oxygen storage components (OSC) to enhance HC, CO oxidation and NOx reduction performance under standard operating conditions where there is rapid perturbation of the air-to-fuel ratio (A/F). The OSC function is required to storage and to release oxygen, however the optimum storage capacity and release rate to maximize HC, CO and NOx conversion varies as a function of engine operating conditions, such as A/F perturbation frequency, amplitude and temperature. At the same time it is necessary for the vehicle on board diagnostics (OBD) systems to monitor that the catalyst OSC is functioning correctly. Detailed understanding of how OSC characteristics can simultaneously match gas performance and OBD functionality are not well known. In this study, several TWC catalysts were prepared with different types of OSC materials such that oxygen storage capacity and activation energy for oxygen release could be varied over a wide range. Five independent variables; OSC species, OSC loading in the catalyst, temperature, A/F amplitude and A/F frequency were controlled and fourteen dependent variables such as gas performance, oxygen sensor response, etc, were measured. Statistical analysis was performed using the multi-objective analysis software, modeFRONTIER.
Description
Three Way Catalysts (TWC) contain oxygen storage components (OSC) to enhance HC, CO oxidation and NOx reduction performance under standard operating conditions where there is rapid perturbation of the air-to-fuel ratio (A/F). The OSC function is required to storage and to release oxygen, however the optimum storage capacity and release rate to maximize HC, CO and NOx conversion varies as a function of engine operating conditions, such as A/F perturbation frequency, amplitude and temperature. At the same time it is necessary for the vehicle on board diagnostics (OBD) systems to monitor that the catalyst OSC is functioning correctly. Detailed understanding of how OSC characteristics can simultaneously match gas performance and OBD functionality are not well known. In this study, several TWC catalysts were prepared with different types of OSC materials such that oxygen storage capacity and activation energy for oxygen release could be varied over a wide range. Five independent variables; OSC species, OSC loading in the catalyst, temperature, A/F amplitude and A/F frequency were controlled and fourteen dependent variables such as gas performance, oxygen sensor response, etc, were measured. Statistical analysis was performed using the multi-objective analysis software, modeFRONTIER.

Suppliers

Company
Product
Description
Supplier Links
Multiple Regression Analysis of OSC Characteristics under Transient TWC Conditions - 2008-01-0713 - SAE International
Warrendale, PA, United States
Multiple Regression Analysis of OSC Characteristics under Transient TWC Conditions
2008-01-0713
Multiple Regression Analysis of OSC Characteristics under Transient TWC Conditions 2008-01-0713
Three Way Catalysts (TWC) contain oxygen storage components (OSC) to enhance HC, CO oxidation and NOx reduction performance under standard operating conditions where there is rapid perturbation of the air-to-fuel ratio (A/F). The OSC function is required to storage and to release oxygen, however the optimum storage capacity and release rate to maximize HC, CO and NOx conversion varies as a function of engine operating conditions, such as A/F perturbation frequency, amplitude and temperature. At the same time it is necessary for the vehicle on board diagnostics (OBD) systems to monitor that the catalyst OSC is functioning correctly. Detailed understanding of how OSC characteristics can simultaneously match gas performance and OBD functionality are not well known. In this study, several TWC catalysts were prepared with different types of OSC materials such that oxygen storage capacity and activation energy for oxygen release could be varied over a wide range. Five independent variables; OSC species, OSC loading in the catalyst, temperature, A/F amplitude and A/F frequency were controlled and fourteen dependent variables such as gas performance, oxygen sensor response, etc, were measured. Statistical analysis was performed using the multi-objective analysis software, modeFRONTIER.

Three Way Catalysts (TWC) contain oxygen storage components (OSC) to enhance HC, CO oxidation and NOx reduction performance under standard operating conditions where there is rapid perturbation of the air-to-fuel ratio (A/F). The OSC function is required to storage and to release oxygen, however the optimum storage capacity and release rate to maximize HC, CO and NOx conversion varies as a function of engine operating conditions, such as A/F perturbation frequency, amplitude and temperature. At the same time it is necessary for the vehicle on board diagnostics (OBD) systems to monitor that the catalyst OSC is functioning correctly. Detailed understanding of how OSC characteristics can simultaneously match gas performance and OBD functionality are not well known. In this study, several TWC catalysts were prepared with different types of OSC materials such that oxygen storage capacity and activation energy for oxygen release could be varied over a wide range. Five independent variables; OSC species, OSC loading in the catalyst, temperature, A/F amplitude and A/F frequency were controlled and fourteen dependent variables such as gas performance, oxygen sensor response, etc, were measured. Statistical analysis was performed using the multi-objective analysis software, modeFRONTIER.

Supplier's Site

Technical Specifications

  SAE International
Product Category Standards and Technical Documents
Product Number 2008-01-0713
Product Name Multiple Regression Analysis of OSC Characteristics under Transient TWC Conditions
Unlock Full Specs
to access all available technical data

Similar Products