Restek Rt®-Alumina BOND/MAPD Columns

Description
Optimized deactivation produces maximum response when analyzing trace levels of acetylene, methyl acetylene, and propadiene. Stable response factors make this column ideal for process-type applications where recalibration must be minimized. High loadability reduces peak tailing and improves separations. Extended temperature range up to 250 °C for fast elution of high molecular weight (HMW) hydrocarbons and accelerated column regeneration following exposure to water. Rt®-Alumina BOND/MAPD PLOT columns are made specifically for the analysis of petrochemicals and downstream products such as ethylene, propylene, butylenes, and butadiene.
Description
Optimized deactivation produces maximum response when analyzing trace levels of acetylene, methyl acetylene, and propadiene. Stable response factors make this column ideal for process-type applications where recalibration must be minimized. High loadability reduces peak tailing and improves separations. Extended temperature range up to 250 °C for fast elution of high molecular weight (HMW) hydrocarbons and accelerated column regeneration following exposure to water. Rt®-Alumina BOND/MAPD PLOT columns are made specifically for the analysis of petrochemicals and downstream products such as ethylene, propylene, butylenes, and butadiene.

Suppliers

Company
Product
Description
Supplier Links
Rt®-Alumina BOND/MAPD Columns -  - Restek
Bellefonte, PA, USA
Rt®-Alumina BOND/MAPD Columns
Rt®-Alumina BOND/MAPD Columns
Optimized deactivation produces maximum response when analyzing trace levels of acetylene, methyl acetylene, and propadiene. Stable response factors make this column ideal for process-type applications where recalibration must be minimized. High loadability reduces peak tailing and improves separations. Extended temperature range up to 250 °C for fast elution of high molecular weight (HMW) hydrocarbons and accelerated column regeneration following exposure to water. Rt®-Alumina BOND/MAPD PLOT columns are made specifically for the analysis of petrochemicals and downstream products such as ethylene, propylene, butylenes, and butadiene.
  • Optimized deactivation produces maximum response when analyzing trace levels of acetylene, methyl acetylene, and propadiene.
  • Stable response factors make this column ideal for process-type applications where recalibration must be minimized.
  • High loadability reduces peak tailing and improves separations.
  • Extended temperature range up to 250 °C for fast elution of high molecular weight (HMW) hydrocarbons and accelerated column regeneration following exposure to water.
    Rt®-Alumina BOND/MAPD PLOT columns are made specifically for the analysis of petrochemicals and downstream products such as ethylene, propylene, butylenes, and butadiene.
Supplier's Site

Technical Specifications

  Restek
Product Category GC Columns
Product Name Rt®-Alumina BOND/MAPD Columns
Column Type Capillary; Porous Layer Open Tubular
Construction Material Silicate Glass; Other; Fused Silica
Column Length 30 to 50 m (98.43 to 164 ft)
Unlock Full Specs
to access all available technical data

Similar Products

Abel Industries Canada Ltd.
Specs
Column Length 50 m (164 ft)
Inner Diameter (ID) 200 µm (7.87 mils)
Film Thickness 0.3300 µm (0.0130 mils)
View Details
MXT®-2887 Column -  - Restek
Specs
Column Type Capillary
Construction Material Stainless Steel
Column Length 10 m (32.81 ft)
View Details
Abel Industries Canada Ltd.
Specs
Column Length 30 m (98.43 ft)
Inner Diameter (ID) 530 µm (20.87 mils)
Film Thickness 0.2500 µm (0.0098 mils)
View Details
Stabilwax®-DB Columns -  - Restek
Specs
Column Type Capillary
Construction Material Silicate Glass; Other; Fused Silica
Column Length 15 to 60 m (49.21 to 197 ft)
View Details