Real Time Automation, Inc. Industrial Control Component Gateways: Connect up to 32 Modbus RTU Servers to a web interface device 460MMWI-N2E-DW

Description
The 460MMWI moves data between a web interface device and up to 32 Modbus RTU Servers. The gateway presents the Modbus data as JSON or XML files transferred via HTTP commands. With the 460MMWI, you are making a direct connection between XML/JSON data and registers or coils in your Modbus RTU Servers. With the 460MMWI, you have a tool to help you map Modbus RTU device data into an XML/JSON device. You can also send XML/JSON data and write them to your Modbus RTU Server devices. Comes with din rail mount and wall wart. Fully configurable Modbus RTU Client Connects up to 32 Modbus RTU Servers Get PLC data table entries encoded in either JSON or XML Bidirectional data transfer supports both HTTP GET and POST Effortless Browser Based Configuration, no programming software is required Simple data translation allows you to manipulate data as it passes between protocols 5 Year Hardware Warranty
Datasheet
Description
The 460MMWI moves data between a web interface device and up to 32 Modbus RTU Servers. The gateway presents the Modbus data as JSON or XML files transferred via HTTP commands. With the 460MMWI, you are making a direct connection between XML/JSON data and registers or coils in your Modbus RTU Servers. With the 460MMWI, you have a tool to help you map Modbus RTU device data into an XML/JSON device. You can also send XML/JSON data and write them to your Modbus RTU Server devices. Comes with din rail mount and wall wart. Fully configurable Modbus RTU Client Connects up to 32 Modbus RTU Servers Get PLC data table entries encoded in either JSON or XML Bidirectional data transfer supports both HTTP GET and POST Effortless Browser Based Configuration, no programming software is required Simple data translation allows you to manipulate data as it passes between protocols 5 Year Hardware Warranty
Datasheet

Suppliers

Company
Product
Description
Supplier Links
Industrial Control Component Gateways: Connect up to 32 Modbus RTU Servers to a web interface device - 460MMWI-N2E-DW - Real Time Automation, Inc.
Pewaukee, WI, United States
Industrial Control Component Gateways: Connect up to 32 Modbus RTU Servers to a web interface device
460MMWI-N2E-DW
Industrial Control Component Gateways: Connect up to 32 Modbus RTU Servers to a web interface device 460MMWI-N2E-DW
The 460MMWI moves data between a web interface device and up to 32 Modbus RTU Servers. The gateway presents the Modbus data as JSON or XML files transferred via HTTP commands. With the 460MMWI, you are making a direct connection between XML/JSON data and registers or coils in your Modbus RTU Servers. With the 460MMWI, you have a tool to help you map Modbus RTU device data into an XML/JSON device. You can also send XML/JSON data and write them to your Modbus RTU Server devices. Comes with din rail mount and wall wart. Fully configurable Modbus RTU Client Connects up to 32 Modbus RTU Servers Get PLC data table entries encoded in either JSON or XML Bidirectional data transfer supports both HTTP GET and POST Effortless Browser Based Configuration, no programming software is required Simple data translation allows you to manipulate data as it passes between protocols 5 Year Hardware Warranty

The 460MMWI moves data between a web interface device and up to 32 Modbus RTU Servers. The gateway presents the Modbus data as JSON or XML files transferred via HTTP commands. With the 460MMWI, you are making a direct connection between XML/JSON data and registers or coils in your Modbus RTU Servers. With the 460MMWI, you have a tool to help you map Modbus RTU device data into an XML/JSON device. You can also send XML/JSON data and write them to your Modbus RTU Server devices. Comes with din rail mount and wall wart.

  • Fully configurable Modbus RTU Client
  • Connects up to 32 Modbus RTU Servers
  • Get PLC data table entries encoded in either JSON or XML
  • Bidirectional data transfer supports both HTTP GET and POST
  • Effortless Browser Based Configuration, no programming software is required
  • Simple data translation allows you to manipulate data as it passes between protocols
  • 5 Year Hardware Warranty
Supplier's Site Datasheet

Technical Specifications

  Real Time Automation, Inc.
Product Category Network Equipment
Product Number 460MMWI-N2E-DW
Product Name Industrial Control Component Gateways: Connect up to 32 Modbus RTU Servers to a web interface device
Network Equipment Gateway
Unlock Full Specs
to access all available technical data

Similar Products

CANwireless with external antenna connection - CR3133 - ifm efector inc.
Specs
Area Network Type CAN
Protocol / Network CAN; WLAN; Bluetooth
View Details
Port Extender for 75 Ohm VNAs - PE0312-75 - Copper Mountain Technologies
Copper Mountain Technologies
Specs
Network Equipment Repeater
Number of Ports 12 #
View Details
LoRa Wireless Gateway - HW500 - Holykell Technology Company Limited
Holykell Technology Company Limited
Specs
Network Equipment Gateway
Network Media Wireless
View Details
CANpro USB -  - Softing Inc. Industrial Automation
Softing Inc. Industrial Automation
Specs
Network Equipment Modem
View Details