Sentinel Positioning Devices

Description
Source Positioning Kits It is recommended that a source stop be held in position with the source positioning kit. The kit is comprised of a tripod stand, adjustable clamp, and clamp holder. Pipe Centering Devices These devices are designed to hold a radiography source in the center of pipes or other cylindrical vessels, and are especially useful where panoramic radiographs are needed. J-TUBE ASSEMBLY - Spring loaded wheel and slide types are available to maintain the source stop in the center of the pipe and yet pass freely over the welds. Used with rigid source tubes the devices can be pushed easily along distances up to the limit of the source projector. They are available with threaded fittings on both ends (compatible with the guide tubes), or the standard male thread at one end and an integral source stop on the other. The standard length is 7 feet. Other lengths are available upon request.
Description
Source Positioning Kits It is recommended that a source stop be held in position with the source positioning kit. The kit is comprised of a tripod stand, adjustable clamp, and clamp holder. Pipe Centering Devices These devices are designed to hold a radiography source in the center of pipes or other cylindrical vessels, and are especially useful where panoramic radiographs are needed. J-TUBE ASSEMBLY - Spring loaded wheel and slide types are available to maintain the source stop in the center of the pipe and yet pass freely over the welds. Used with rigid source tubes the devices can be pushed easily along distances up to the limit of the source projector. They are available with threaded fittings on both ends (compatible with the guide tubes), or the standard male thread at one end and an integral source stop on the other. The standard length is 7 feet. Other lengths are available upon request.

Suppliers

Company
Product
Description
Supplier Links
Positioning Devices -  - Sentinel
Baton Rouge, LA, USA
Positioning Devices
Positioning Devices
Source Positioning Kits It is recommended that a source stop be held in position with the source positioning kit. The kit is comprised of a tripod stand, adjustable clamp, and clamp holder. Pipe Centering Devices These devices are designed to hold a radiography source in the center of pipes or other cylindrical vessels, and are especially useful where panoramic radiographs are needed. J-TUBE ASSEMBLY - Spring loaded wheel and slide types are available to maintain the source stop in the center of the pipe and yet pass freely over the welds. Used with rigid source tubes the devices can be pushed easily along distances up to the limit of the source projector. They are available with threaded fittings on both ends (compatible with the guide tubes), or the standard male thread at one end and an integral source stop on the other. The standard length is 7 feet. Other lengths are available upon request.

Source Positioning Kits

It is recommended that a source stop be held in position with the source positioning kit. The kit is comprised of a tripod stand, adjustable clamp, and clamp holder.

Pipe Centering Devices

These devices are designed to hold a radiography source in the center of pipes or other cylindrical vessels, and are especially useful where panoramic radiographs are needed.
J-TUBE ASSEMBLY - Spring loaded wheel and slide types are available to maintain the source stop in the center of the pipe and yet pass freely over the welds. Used with rigid source tubes the devices can be pushed easily along distances up to the limit of the source projector. They are available with threaded fittings on both ends (compatible with the guide tubes), or the standard male thread at one end and an integral source stop on the other. The standard length is 7 feet. Other lengths are available upon request.

Supplier's Site

Technical Specifications

  Sentinel
Product Category Nondestructive Testing (NDT) Supplies and Accessories
Product Name Positioning Devices
X-ray / Radiographic Inspection Positioning Devices
Unlock Full Specs
to access all available technical data

Similar Products

Cables -  - Evident Scientific
Evident Scientific
Specs
General Supplies & Accessories Cable / Adapter
View Details
Industrial X-ray, Non-Destructive Testing (NDT) Rooms -  - MarShield
Specs
X-ray / Radiographic Inspection Shielding / Interlock / Enclosure
View Details
Non-Destructive Testing - Fluorescent Penetrants (Type I) - Ardrox 9812, 9813, and 9814 - Chemetall
Specs
Penetrant Testing (Dye / FPI) Fluorescent Material; Penetrant or dye penetrant
View Details
INDUSTREX Manual Developer -  - Carestream NDT
Specs
X-ray / Radiographic Inspection Film Chemicals / Developer
View Details