Nova Analytical Systems Inc. Process Analyzer for Carbon Monoxide Model 481RM

Description
The Nova 481 Series CO analyzers utilize a simple and reliable microprocessor-based non-dispersive infrared detector specific to CO. The detector pulses an infrared beam of light through the sample tube, without the need for a mechanical chopper. In operation, the internal sample pump draws the sample gas through the filter/condensate trap, secondary filter, flowmeter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent or PPM CO on the digital meter. The output is also available as an analog or digital signal.
Description
The Nova 481 Series CO analyzers utilize a simple and reliable microprocessor-based non-dispersive infrared detector specific to CO. The detector pulses an infrared beam of light through the sample tube, without the need for a mechanical chopper. In operation, the internal sample pump draws the sample gas through the filter/condensate trap, secondary filter, flowmeter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent or PPM CO on the digital meter. The output is also available as an analog or digital signal.

Suppliers

Company
Product
Description
Supplier Links
Process Analyzer for Carbon Monoxide - Model 481RM - Nova Analytical Systems Inc.
Niagara Falls, NY, USA
Process Analyzer for Carbon Monoxide
Model 481RM
Process Analyzer for Carbon Monoxide Model 481RM
The Nova 481 Series CO analyzers utilize a simple and reliable microprocessor-based non-dispersive infrared detector specific to CO. The detector pulses an infrared beam of light through the sample tube, without the need for a mechanical chopper. In operation, the internal sample pump draws the sample gas through the filter/condensate trap, secondary filter, flowmeter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent or PPM CO on the digital meter. The output is also available as an analog or digital signal.

The Nova 481 Series CO analyzers utilize a simple and reliable microprocessor-based non-dispersive infrared detector specific to CO. The detector pulses an infrared beam of light through the sample tube, without the need for a mechanical chopper. In operation, the internal sample pump draws the sample gas through the filter/condensate trap, secondary filter, flowmeter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent or PPM CO on the digital meter. The output is also available as an analog or digital signal.

Supplier's Site

Technical Specifications

  Nova Analytical Systems Inc.
Product Category Gas Instruments
Product Number Model 481RM
Product Name Process Analyzer for Carbon Monoxide
Measurement Type %Volume
Application Process Gas
Gas Types Toxic; CO; (0-100%)
Electrical Outputs Current
Display Digital
Unlock Full Specs
to access all available technical data

Similar Products

Airborne Particle-Counting Hygiene Meter - PCE-RCM 12 - PCE Instruments / PCE Americas Inc.
Specs
Gas Types Toxic; Combustible; CO2; (0 ... 9999 ppm); Water Vapor; (0 ... 100 % r.H.); (Formaldehyde (HCHO))
Display Digital
Instrument Type Detector
View Details
Flame Ionization Detector - SNR650 - Control Instruments Corp.
Control Instruments Corp.
Specs
Measurement Type Trace
Application Continuous Emissions Monitoring; Ambient Air Monitoring; Process Gas
Gas Types Hydrocarbons; (10-20000 ppm as propane, 30-60000 ppm Cv); Methane (CH4) / Natural Gas
View Details
Portable Infrared Gas Analyzer - ZSV Series - Fuji Electric Corp. of America
Fuji Electric Corp. of America
Specs
Application Confined Space Entry
Gas Types CO2; (0-200ppm); CO; (0-200ppm); Methane (CH4) / Natural Gas; (0-1000ppm); NO; (0-500ppm); O2; (0 to 5%); SO2; (0-500ppm)
Electrical Outputs Current
View Details
Replacement Cassettes for Vertex Legacy Systems -  - DOD Technologies Inc.
Specs
Mounting Type Fixed
Sensor Technology Colorimetric
View Details