Nova Analytical Systems Inc. Process Analyzer for Sulfur Dioxide Model 460D2

Description
The Nova 460 Series SO2 analyzers utilize a reliable microprocessor-based non-dispersive infrared detector specific to SO2. In operation, the internal sample pump draws the sample gas through the filter/condensate trap, secondary filter, flow meter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent or PPM SO2 on the digital meter. The output is also available as an analog or digital signal.
Description
The Nova 460 Series SO2 analyzers utilize a reliable microprocessor-based non-dispersive infrared detector specific to SO2. In operation, the internal sample pump draws the sample gas through the filter/condensate trap, secondary filter, flow meter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent or PPM SO2 on the digital meter. The output is also available as an analog or digital signal.

Suppliers

Company
Product
Description
Supplier Links
Process Analyzer for Sulfur Dioxide - Model 460D2 - Nova Analytical Systems Inc.
Niagara Falls, NY, USA
Process Analyzer for Sulfur Dioxide
Model 460D2
Process Analyzer for Sulfur Dioxide Model 460D2
The Nova 460 Series SO2 analyzers utilize a reliable microprocessor-based non-dispersive infrared detector specific to SO2. In operation, the internal sample pump draws the sample gas through the filter/condensate trap, secondary filter, flow meter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent or PPM SO2 on the digital meter. The output is also available as an analog or digital signal.

The Nova 460 Series SO2 analyzers utilize a reliable microprocessor-based non-dispersive infrared detector specific to SO2. In operation, the internal sample pump draws the sample gas through the filter/condensate trap, secondary filter, flow meter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent or PPM SO2 on the digital meter. The output is also available as an analog or digital signal.

Supplier's Site

Technical Specifications

  Nova Analytical Systems Inc.
Product Category Gas Instruments
Product Number Model 460D2
Product Name Process Analyzer for Sulfur Dioxide
Measurement Type %Volume (optional feature); Trace (optional feature)
Application Process Gas
Gas Types Toxic; SO2; (0-100%, 0-5000 ppm)
Electrical Outputs Current
Display Digital
Unlock Full Specs
to access all available technical data

Similar Products

Fixed Multi-Gas Detector -  - CO2Meter.com
Specs
Measurement Type %Volume
Gas Types (Dependent upon gas sensors selected)
Number of Gases Monitored Multi
View Details
Airborne Particle-Counting Hygiene Meter - PCE-RCM 12 - PCE Instruments / PCE Americas Inc.
Specs
Gas Types Toxic; Combustible; CO2; (0 ... 9999 ppm); Water Vapor; (0 ... 100 % r.H.); (Formaldehyde (HCHO))
Display Digital
Instrument Type Detector
View Details
Flue Gas Oxygen Analyzer - WDG 1200 - LAND
Specs
Measurement Type %Volume
Application Continuous Emissions Monitoring
Gas Types Toxic; O2; (From 0 to 1 %, 0 to 25 %)
View Details
AII-3000-AHCD Handheld O2 Analyzer -  - Analytical Industries Inc.
Analytical Industries Inc.
Specs
Gas Types O2
Display Digital
Instrument Type Analyzer
View Details