NACE International TM0113-2013-SG "Evaluating the Accuracy of Field-Grade Reference Electrodes" 21265-SG

Description
This standard describes a test method for evaluating the accuracy of field-grade reference electrodes used for obtaining field measurement of structure-to-electro lyte potentials. The test method described in this standard is a relatively quick, simple, and inexpensive way to evaluate the accuracy of a field-grade reference electrode. The test method measures the potential difference between the field-grade electrode and a master reference electrode. Key words: field-grade reference electrodes, copper, sulfate, silver, chloride, TM0101, TM0497
Description
This standard describes a test method for evaluating the accuracy of field-grade reference electrodes used for obtaining field measurement of structure-to-electro lyte potentials. The test method described in this standard is a relatively quick, simple, and inexpensive way to evaluate the accuracy of a field-grade reference electrode. The test method measures the potential difference between the field-grade electrode and a master reference electrode. Key words: field-grade reference electrodes, copper, sulfate, silver, chloride, TM0101, TM0497

Suppliers

Company
Product
Description
Supplier Links
TM0113-2013-SG
Houston, TX, United States
TM0113-2013-SG "Evaluating the Accuracy of Field-Grade Reference Electrodes"
21265-SG
TM0113-2013-SG "Evaluating the Accuracy of Field-Grade Reference Electrodes" 21265-SG
This standard describes a test method for evaluating the accuracy of field-grade reference electrodes used for obtaining field measurement of structure-to-electro lyte potentials. The test method described in this standard is a relatively quick, simple, and inexpensive way to evaluate the accuracy of a field-grade reference electrode. The test method measures the potential difference between the field-grade electrode and a master reference electrode. Key words: field-grade reference electrodes, copper, sulfate, silver, chloride, TM0101, TM0497

This standard describes a test method for evaluating the accuracy of field-grade reference electrodes used for obtaining field measurement of structure-to-electrolyte potentials. The test method described in this standard is a relatively quick, simple, and inexpensive way to evaluate the accuracy of a field-grade reference electrode. The test method measures the potential difference between the field-grade electrode and a master reference electrode.
Key words: field-grade reference electrodes, copper, sulfate, silver, chloride, TM0101, TM0497

Supplier's Site