Meter Group Moisture Meter

Description
Multi-sample Moisture Content Analyzer Measure the moisture content of nine soil samples with just four minutes of hands-on work time. How it Works To start a measurement, place up to 9 soil samples in TrueDry's rotating tray, close the lid, and select a program. Select Temperature and Time TrueDry lets you select the drying temperature and time (or alternatively, allows you to dry to constant weight). Monitor Weight Automatically As the sample dries, TrueDry monitors the weight automatically, cycling each sample onto a high precision electromagnetic balance for repeated weight measurements. Dry to a Standard TrueDry finishes the drying process by passing heated, dessicated air over the sample. Each sample is dried to a uniform value of 1% relative humidity. Eliminate Error Due to Ambient Conditions Differences in ambient humidity can cause significant variation in oven dry values. The enclosed sample chamber protects the sample from ambient temperature and humidity effects to provide consistent results. Just One Interruption TrueDry gives you the precision of a drying oven without moving samples between balances, ovens, and dessicators--just one interruption of your workflow to measure nine samples. Controlled Contact Drying Using a method called "controlled contact drying," TrueDry heats the sample, not the sample chamber. Heater coils and sensors are located just millimeters from each individual sample for precise temperature control. Save Electricity and Labor Costs You may only run a few samples, but your lab oven is probably on most of the time. Running constantly, TrueDry will use just 25% of the energy of a lab oven. As typically used, it requires even less.
Description
Multi-sample Moisture Content Analyzer Measure the moisture content of nine soil samples with just four minutes of hands-on work time. How it Works To start a measurement, place up to 9 soil samples in TrueDry's rotating tray, close the lid, and select a program. Select Temperature and Time TrueDry lets you select the drying temperature and time (or alternatively, allows you to dry to constant weight). Monitor Weight Automatically As the sample dries, TrueDry monitors the weight automatically, cycling each sample onto a high precision electromagnetic balance for repeated weight measurements. Dry to a Standard TrueDry finishes the drying process by passing heated, dessicated air over the sample. Each sample is dried to a uniform value of 1% relative humidity. Eliminate Error Due to Ambient Conditions Differences in ambient humidity can cause significant variation in oven dry values. The enclosed sample chamber protects the sample from ambient temperature and humidity effects to provide consistent results. Just One Interruption TrueDry gives you the precision of a drying oven without moving samples between balances, ovens, and dessicators--just one interruption of your workflow to measure nine samples. Controlled Contact Drying Using a method called "controlled contact drying," TrueDry heats the sample, not the sample chamber. Heater coils and sensors are located just millimeters from each individual sample for precise temperature control. Save Electricity and Labor Costs You may only run a few samples, but your lab oven is probably on most of the time. Running constantly, TrueDry will use just 25% of the energy of a lab oven. As typically used, it requires even less.

Suppliers

Company
Product
Description
Supplier Links
Pullman, WA, USA
Moisture Meter
Moisture Meter
Multi-sample Moisture Content Analyzer Measure the moisture content of nine soil samples with just four minutes of hands-on work time. How it Works To start a measurement, place up to 9 soil samples in TrueDry's rotating tray, close the lid, and select a program. Select Temperature and Time TrueDry lets you select the drying temperature and time (or alternatively, allows you to dry to constant weight). Monitor Weight Automatically As the sample dries, TrueDry monitors the weight automatically, cycling each sample onto a high precision electromagnetic balance for repeated weight measurements. Dry to a Standard TrueDry finishes the drying process by passing heated, dessicated air over the sample. Each sample is dried to a uniform value of 1% relative humidity. Eliminate Error Due to Ambient Conditions Differences in ambient humidity can cause significant variation in oven dry values. The enclosed sample chamber protects the sample from ambient temperature and humidity effects to provide consistent results. Just One Interruption TrueDry gives you the precision of a drying oven without moving samples between balances, ovens, and dessicators--just one interruption of your workflow to measure nine samples. Controlled Contact Drying Using a method called "controlled contact drying," TrueDry heats the sample, not the sample chamber. Heater coils and sensors are located just millimeters from each individual sample for precise temperature control. Save Electricity and Labor Costs You may only run a few samples, but your lab oven is probably on most of the time. Running constantly, TrueDry will use just 25% of the energy of a lab oven. As typically used, it requires even less.

Multi-sample Moisture Content Analyzer

Measure the moisture content of nine soil samples with just four minutes of hands-on work time.

How it Works

To start a measurement, place up to 9 soil samples in TrueDry's rotating tray, close the lid, and select a program.

Select Temperature and Time

TrueDry lets you select the drying temperature and time (or alternatively, allows you to dry to constant weight).

Monitor Weight Automatically

As the sample dries, TrueDry monitors the weight automatically, cycling each sample onto a high precision electromagnetic balance for repeated weight measurements.

Dry to a Standard

TrueDry finishes the drying process by passing heated, dessicated air over the sample. Each sample is dried to a uniform value of 1% relative humidity.

Eliminate Error Due to Ambient Conditions

Differences in ambient humidity can cause significant variation in oven dry values. The enclosed sample chamber protects the sample from ambient temperature and humidity effects to provide consistent results.

Just One Interruption

TrueDry gives you the precision of a drying oven without moving samples between balances, ovens, and dessicators--just one interruption of your workflow to measure nine samples.

Controlled Contact Drying

Using a method called "controlled contact drying," TrueDry heats the sample, not the sample chamber. Heater coils and sensors are located just millimeters from each individual sample for precise temperature control.

Save Electricity and Labor Costs

You may only run a few samples, but your lab oven is probably on most of the time. Running constantly, TrueDry will use just 25% of the energy of a lab oven. As typically used, it requires even less.

Supplier's Site

Technical Specifications

  Meter Group
Product Category Moisture Meters
Product Name Moisture Meter
Application Moisture / Water Content in Powder / Solids
Variables Measured Moisture Content
Form Factor Meter
Unlock Full Specs
to access all available technical data

Similar Products

Air Humidity Meter - PCE-THB 40 - PCE Instruments / PCE Americas Inc.
PCE Instruments / PCE Americas Inc.
Specs
Features Battery Powered
Variables Measured Relative Humidity; Pressure; Temperature
Form Factor Meter
View Details
Capacitive Humidity Sensor P14-W - P14-W (150pF ±50pF) - Innovative Sensor Technology IST USA Division
Innovative Sensor Technology IST USA Division
Specs
Operating Temp -58 to 302 F (-50 to 150 C)
View Details
Humidity Sensors - 20027957-50 - TE Connectivity
Specs
Form Factor Sensor
Relative Humidity Range 0.0 to 100 %
Operating Temp -22 to 167 F (-30 to 75 C)
View Details
2 suppliers
Chilled Mirror Hygrometer - Optica Series - Panametrics
Specs
Technology ChillMirror
Application Moisture / Water Content in Gases / Air
Features Datalogger
View Details