LayerZero Power Systems, Inc. Power Distribution Unit Type-P

Description
The Type-P design provides switching between two independent power sources on the primary side of two transformers providing dual power-path distribution capability. Prior to 2003, because of transformer inrush from out-of-phase transfers, you would have found the static switch on the secondary side of two transformers and you could only power the load by one or the other. But today, thanks to LayerZero’s Dynamic Phase Compensation Patent, the saturation current from out-of-phase transfers is minimized. Up to 24 subfeed circuit breakers are available.
Datasheet
Description
The Type-P design provides switching between two independent power sources on the primary side of two transformers providing dual power-path distribution capability. Prior to 2003, because of transformer inrush from out-of-phase transfers, you would have found the static switch on the secondary side of two transformers and you could only power the load by one or the other. But today, thanks to LayerZero’s Dynamic Phase Compensation Patent, the saturation current from out-of-phase transfers is minimized. Up to 24 subfeed circuit breakers are available.
Datasheet

Suppliers

Company
Product
Description
Supplier Links
Power Distribution Unit - Type-P - LayerZero Power Systems, Inc.
Aurora, OH, USA
Power Distribution Unit
Type-P
Power Distribution Unit Type-P
The Type-P design provides switching between two independent power sources on the primary side of two transformers providing dual power-path distribution capability. Prior to 2003, because of transformer inrush from out-of-phase transfers, you would have found the static switch on the secondary side of two transformers and you could only power the load by one or the other. But today, thanks to LayerZero’s Dynamic Phase Compensation Patent, the saturation current from out-of-phase transfers is minimized. Up to 24 subfeed circuit breakers are available.

The Type-P design provides switching between two independent power sources on the primary side of two transformers providing dual power-path distribution capability. Prior to 2003, because of transformer inrush from out-of-phase transfers, you would have found the static switch on the secondary side of two transformers and you could only power the load by one or the other. But today, thanks to LayerZero’s Dynamic Phase Compensation Patent, the saturation current from out-of-phase transfers is minimized. Up to 24 subfeed circuit breakers are available.

Supplier's Site Datasheet

Technical Specifications

  LayerZero Power Systems, Inc.
Product Category Power Distribution Units (PDU)
Product Number Type-P
Product Name Power Distribution Unit
Voltage 208V (optional feature); 380, 400, 415, 480, 600V
Frequency 50Hz (optional feature); 60Hz (optional feature)
Phase Three
Number of Outlets 12
Current 800.0 amps
Unlock Full Specs
to access all available technical data

Similar Products

PDUs and Outlet Strips - 1584S10 - Hammond Manufacturing Company Inc.
Hammond Manufacturing Company Inc.
Specs
Certifications REACH
View Details
MDS2 Series Modular Distribution Systems -  - Sensata Technologies
Specs
Current 600.0 amps
Unit Type Modular
Operating Temperature -40 to 185 F (-40 to 85 C)
View Details