Description
2 cc coupled cavity, resonant frequency = 22.4 kHz CRY319 is a kind of coupled cavity with the volume of 2 cc in accordance with IEC 60318-5. It can be adapted to 1/2'' pressure-field measurement microphones according to IEC 61094-4 (WS2P), such as CRY372, CRY332, CRY334 and other measurement microphones. Hearing aids and headphones for air conduction are connected to the coupled cavity by ear inserts (e.g. ear molds or similar devices). The coupler has a resonant frequency of 22.4 kHz to avoid interference with measurements within the audible frequency range. This coupled cavity kit has a built-in CRY372 measurement microphone with the sensitivity of 12.5 mV/Pa and the noise floor of 20 dB(A).
Datasheet
Description
2 cc coupled cavity, resonant frequency = 22.4 kHz CRY319 is a kind of coupled cavity with the volume of 2 cc in accordance with IEC 60318-5. It can be adapted to 1/2'' pressure-field measurement microphones according to IEC 61094-4 (WS2P), such as CRY372, CRY332, CRY334 and other measurement microphones. Hearing aids and headphones for air conduction are connected to the coupled cavity by ear inserts (e.g. ear molds or similar devices). The coupler has a resonant frequency of 22.4 kHz to avoid interference with measurements within the audible frequency range. This coupled cavity kit has a built-in CRY372 measurement microphone with the sensitivity of 12.5 mV/Pa and the noise floor of 20 dB(A).
Datasheet

Suppliers

Company
Product
Description
Supplier Links
Ear simulator/coupler - CRY319 - Hangzhou Crysound Electronics Co., Ltd.
Yuhang District, Hangzhou, Zhejiang, China
Ear simulator/coupler
CRY319
Ear simulator/coupler CRY319
2 cc coupled cavity, resonant frequency = 22.4 kHz CRY319 is a kind of coupled cavity with the volume of 2 cc in accordance with IEC 60318-5. It can be adapted to 1/2'' pressure-field measurement microphones according to IEC 61094-4 (WS2P), such as CRY372, CRY332, CRY334 and other measurement microphones. Hearing aids and headphones for air conduction are connected to the coupled cavity by ear inserts (e.g. ear molds or similar devices). The coupler has a resonant frequency of 22.4 kHz to avoid interference with measurements within the audible frequency range. This coupled cavity kit has a built-in CRY372 measurement microphone with the sensitivity of 12.5 mV/Pa and the noise floor of 20 dB(A).

2 cc coupled cavity, resonant frequency = 22.4 kHz

CRY319 is a kind of coupled cavity with the volume of 2 cc in accordance with IEC 60318-5. It can be adapted to 1/2'' pressure-field measurement microphones according to IEC 61094-4 (WS2P), such as CRY372, CRY332, CRY334 and other measurement microphones. Hearing aids and headphones for air conduction are connected to the coupled cavity by ear inserts (e.g. ear molds or similar devices). The coupler has a resonant frequency of 22.4 kHz to avoid interference with measurements within the audible frequency range. This coupled cavity kit has a built-in CRY372 measurement microphone with the sensitivity of 12.5 mV/Pa and the noise floor of 20 dB(A).

Supplier's Site Datasheet

Technical Specifications

  Hangzhou Crysound Electronics Co., Ltd.
Product Category Uncategorized Products
Product Number CRY319
Product Name Ear simulator/coupler
Unlock Full Specs