FIS Inc. Sensor Gas Chromatograph - Ammonia/Trimethylamine Analyzer ODNA-P2

Description
Sensor Gas Chromatograph (SGC) uses a highly sensitive semiconductor gas sensor as a gas detector. The original built-in column is small, enabling the sample gases to be very sensitive and quick separation.
Description
Sensor Gas Chromatograph (SGC) uses a highly sensitive semiconductor gas sensor as a gas detector. The original built-in column is small, enabling the sample gases to be very sensitive and quick separation.

Suppliers

Company
Product
Description
Supplier Links
Sensor Gas Chromatograph - Ammonia/Trimethylamine Analyzer - ODNA-P2 - FIS Inc.
Edmonds, WA, United States
Sensor Gas Chromatograph - Ammonia/Trimethylamine Analyzer
ODNA-P2
Sensor Gas Chromatograph - Ammonia/Trimethylamine Analyzer ODNA-P2
Sensor Gas Chromatograph (SGC) uses a highly sensitive semiconductor gas sensor as a gas detector. The original built-in column is small, enabling the sample gases to be very sensitive and quick separation.

Sensor Gas Chromatograph (SGC) uses a highly sensitive semiconductor gas sensor as a gas detector. The original built-in column is small, enabling the sample gases to be very sensitive and quick separation.

Supplier's Site

Technical Specifications

  FIS Inc.
Product Category Gas Instruments
Product Number ODNA-P2
Product Name Sensor Gas Chromatograph - Ammonia/Trimethylamine Analyzer
Measurement Type Trace
Application Process Gas
Gas Types NH3; (50ppb-100ppm); (Trimethylamine: 50ppb-100ppm)
Display Analog
Instrument Type Analyzer
Unlock Full Specs
to access all available technical data

Similar Products

Gas Monitor - General Monitors S5000 - MSA Safety
Specs
Measurement Type %LEL or %LFL; %Volume; Trace
Application Ambient Air Monitoring; Process Gas
Gas Types Toxic; Combustible; NH3; (0-100 ppm, 0-1000 ppm); CO2; (0-2000, 0-5000, 0-10000, 0-30000, 0-50000 ppm); CO; (0-100, 0-500, 0-1000 ppm); Cl2; (0-5, 0-10. 0-20 ppm); Hydrocarbons; (0-100% LEL); H2; (0-1000 ppm); HCl; (0-50ppm); H2S; (0-10, 0-20, 0-50, 0-100, 0-500 ppm); Methane (CH4) / Natural Gas; (0-100% LEL); NO; (0-100ppm); NO2; (0-10 ppm); O2; (0-25 %); SO2; (0-25 ppm, 0-100 ppm)
View Details
Flame Ionization Detector - SNR650 - Control Instruments Corp.
Control Instruments Corp.
Specs
Measurement Type Trace
Application Continuous Emissions Monitoring; Ambient Air Monitoring; Process Gas
Gas Types Hydrocarbons; (10-20000 ppm as propane, 30-60000 ppm Cv); Methane (CH4) / Natural Gas
View Details
Refrigerant Leak Sensor / Transmitter - VOC-3 Series - Acme Engineering Products
Specs
Measurement Type Trace
Application Confined Space Entry
Gas Types Toxic; Refrigerants; (0-1000 PPM)
View Details
ARA300 Personal O2 Detector -  - DOD Technologies Inc.
DOD Technologies Inc.
Specs
Gas Types O2
Display Digital
Features Audible or Visual Alarms; Data Logger; Intrinsically Safe
View Details