FIS Inc. OralChroma™ - Breath Testing Device CHM-2

Description
Three major halitosis components are hydrogen sulfide, methyl mercaptan, and dimethyl sulfide. The OralChroma measures Volatile Sulfide Components (VSC) in the breath and separates them into the above three components. About 1000 sets of OralChroma have been supplied to dentists, universities, and laboratories in the world since 2002. Separating halitosis into three major components with high precision Since the OralChroma uses gas chromatography technology, causes of halitosis can be precisely analyzed to confirm breath odor diagnostics treatment.
Description
Three major halitosis components are hydrogen sulfide, methyl mercaptan, and dimethyl sulfide. The OralChroma measures Volatile Sulfide Components (VSC) in the breath and separates them into the above three components. About 1000 sets of OralChroma have been supplied to dentists, universities, and laboratories in the world since 2002. Separating halitosis into three major components with high precision Since the OralChroma uses gas chromatography technology, causes of halitosis can be precisely analyzed to confirm breath odor diagnostics treatment.

Suppliers

Company
Product
Description
Supplier Links
OralChroma™ - Breath Testing Device - CHM-2 - FIS Inc.
Edmonds, WA, United States
OralChroma™ - Breath Testing Device
CHM-2
OralChroma™ - Breath Testing Device CHM-2
Three major halitosis components are hydrogen sulfide, methyl mercaptan, and dimethyl sulfide. The OralChroma measures Volatile Sulfide Components (VSC) in the breath and separates them into the above three components. About 1000 sets of OralChroma have been supplied to dentists, universities, and laboratories in the world since 2002. Separating halitosis into three major components with high precision Since the OralChroma uses gas chromatography technology, causes of halitosis can be precisely analyzed to confirm breath odor diagnostics treatment.

Three major halitosis components are hydrogen sulfide, methyl mercaptan, and dimethyl sulfide. The OralChroma measures Volatile Sulfide Components (VSC) in the breath and separates them into the above three components. About 1000 sets of OralChroma have been supplied to dentists, universities, and laboratories in the world since 2002.

Separating halitosis into three major components with high precision

Since the OralChroma uses gas chromatography technology, causes of halitosis can be precisely analyzed to confirm breath odor diagnostics treatment.

Supplier's Site

Technical Specifications

  FIS Inc.
Product Category Gas Chromatographs
Product Number CHM-2
Product Name OralChroma™ - Breath Testing Device
Instrument Type Portable
Application Environmental; Medical / Biological
Injection Method Syringe Injection
Display None
General Features Programmable
Unlock Full Specs
to access all available technical data

Similar Products

Natural Gas Chromatograph - Portable NGC - ABB Measurement & Analytics
Specs
Instrument Type Portable
Application Energy
Number of Injection Ports 0.0
View Details
Specs
Instrument Type Fixtured
Application Agricultural Chemicals / Pesticides
Carrier Gas Text He, H2
View Details
COSA Portable BTU Gas Chromatograph -  - COSA Xentaur Corporation
Specs
Instrument Type Portable
Application Energy; Industrial Gases
Display None
View Details
Sensor Gas Chromatograph - Breath Analyzer - SGEA-P2 - FIS Inc.
Specs
Instrument Type Portable
Application Environmental; Medical / Biological
Injection Method Syringe Injection
View Details