Edgetech Instruments Inc. Trace Moisture Analyzer PPM1

Description
The Edgetech Instruments PPM1 is a trace moisture analyzer for monitoring dew/frost point and ppmV water vapor in gases. The PPM1 is a modular, remotely mounted hygrometer configured to meet your moisture measurement application requirements. The PPM1 uses an electrolytic, phosphorus pentoxide sensor in combination with a proprietary semi permeable diffusion membrane. The principle of operation applies Faraday’s Law of Electrolysis to determine the water vapor content by measuring the dissociation current needed to electrolyze the water molecules in the sample. The PPM1 is packaged in an IP66/67, NEMA 4 plastic enclosure and comes complete with two FORM A relay alarms, two analog current outputs and a RS-232 bi-directional serial interface. All Edgetech Instruments hygrometers are manufactured and supported in the USA in a modern, ISO 9001:2015 registered, ISO/IEC 17025:2005 accredited facility. All calibrations and certifications are traceable to NIST. Sensitivity below 1ppm Fast response Long sensor life Low cost Fundamental measurement of moisture content Displays / outputs—dew point (C/F) and PPM values
Datasheet
Description
The Edgetech Instruments PPM1 is a trace moisture analyzer for monitoring dew/frost point and ppmV water vapor in gases. The PPM1 is a modular, remotely mounted hygrometer configured to meet your moisture measurement application requirements. The PPM1 uses an electrolytic, phosphorus pentoxide sensor in combination with a proprietary semi permeable diffusion membrane. The principle of operation applies Faraday’s Law of Electrolysis to determine the water vapor content by measuring the dissociation current needed to electrolyze the water molecules in the sample. The PPM1 is packaged in an IP66/67, NEMA 4 plastic enclosure and comes complete with two FORM A relay alarms, two analog current outputs and a RS-232 bi-directional serial interface. All Edgetech Instruments hygrometers are manufactured and supported in the USA in a modern, ISO 9001:2015 registered, ISO/IEC 17025:2005 accredited facility. All calibrations and certifications are traceable to NIST. Sensitivity below 1ppm Fast response Long sensor life Low cost Fundamental measurement of moisture content Displays / outputs—dew point (C/F) and PPM values
Datasheet

Suppliers

Company
Product
Description
Supplier Links
Trace Moisture Analyzer - PPM1 - Edgetech Instruments Inc.
Hudson, MA, United States
Trace Moisture Analyzer
PPM1
Trace Moisture Analyzer PPM1
The Edgetech Instruments PPM1 is a trace moisture analyzer for monitoring dew/frost point and ppmV water vapor in gases. The PPM1 is a modular, remotely mounted hygrometer configured to meet your moisture measurement application requirements. The PPM1 uses an electrolytic, phosphorus pentoxide sensor in combination with a proprietary semi permeable diffusion membrane. The principle of operation applies Faraday’s Law of Electrolysis to determine the water vapor content by measuring the dissociation current needed to electrolyze the water molecules in the sample. The PPM1 is packaged in an IP66/67, NEMA 4 plastic enclosure and comes complete with two FORM A relay alarms, two analog current outputs and a RS-232 bi-directional serial interface. All Edgetech Instruments hygrometers are manufactured and supported in the USA in a modern, ISO 9001:2015 registered, ISO/IEC 17025:2005 accredited facility. All calibrations and certifications are traceable to NIST. Sensitivity below 1ppm Fast response Long sensor life Low cost Fundamental measurement of moisture content Displays / outputs—dew point (C/F) and PPM values

The Edgetech Instruments PPM1 is a trace moisture analyzer for monitoring dew/frost point and ppmV water vapor in gases.

The PPM1 is a modular, remotely mounted hygrometer configured to meet your moisture measurement application requirements.

The PPM1 uses an electrolytic, phosphorus pentoxide sensor in combination with a proprietary semi permeable diffusion membrane. The principle of operation applies Faraday’s Law of Electrolysis to determine the water vapor content by measuring the dissociation current needed to electrolyze the water molecules in the sample.

The PPM1 is packaged in an IP66/67, NEMA 4 plastic enclosure and comes complete with two FORM A relay alarms, two analog current outputs and a RS-232 bi-directional serial interface.

All Edgetech Instruments hygrometers are manufactured and supported in the USA in a modern, ISO 9001:2015 registered, ISO/IEC 17025:2005 accredited facility. All calibrations and certifications are traceable to NIST.

  • Sensitivity below 1ppm
  • Fast response
  • Long sensor life
  • Low cost
  • Fundamental measurement of moisture content
  • Displays / outputs—dew point (C/F) and PPM values
Supplier's Site Datasheet

Technical Specifications

  Edgetech Instruments Inc.
Product Category Gas Instruments
Product Number PPM1
Product Name Trace Moisture Analyzer
Measurement Type Trace
Application Process Gas
Gas Types Water Vapor; (0.1-1250 ppmv)
Electrical Outputs Current
Display Digital
Unlock Full Specs
to access all available technical data

Similar Products

Infrared Gas Monitor - IR400 - MSA Safety
Specs
Measurement Type %LEL or %LFL; %Volume
Application Ambient Air Monitoring; Process Gas
Gas Types Toxic; Combustible; Hydrocarbons; (0 to 100% LEL); Methane (CH4) / Natural Gas; (0 to 100% by Volume)
View Details
Thermal Conductivity Binary Gas Analyzer - XMTCpro - Panametrics
Specs
Measurement Type %Volume
Application Process Gas
Gas Types CO2; H2; Methane (CH4) / Natural Gas; O2; SO2; (He, N2, Ar)
View Details
XP-703DIII PPB Toxic Gas Handheld Detector -  - DOD Technologies Inc.
Specs
Display Digital
Features Audible or Visual Alarms; Data Logger
Instrument Type Detector
View Details
Flame Ionization Detector - SNR650 - Control Instruments Corp.
Control Instruments Corp.
Specs
Measurement Type Trace
Application Continuous Emissions Monitoring; Ambient Air Monitoring; Process Gas
Gas Types Hydrocarbons; (10-20000 ppm as propane, 30-60000 ppm Cv); Methane (CH4) / Natural Gas
View Details