E+E Elektronik Duct Mount CO2 Switch EE85

Description
EE85 is optimized for building automation as well as for process control applications. It measures CO2 concentration based on the Non-Dispersive Infrared (NDIR) technology. A patented autocalibration procedure compensates for the aging of the infrared source and leads to outstanding long-term stability. The air from the duct flows through the probe into the EE85 enclosure and back into the duct. Inside the enclosure the air diffuses through a membrane into the CO2 sensing cell. As there is no flow through the sensing cell, this is very well protected against dust. EE85 is available with measuring ranges of 0...2000, 0...5000 or 0...10000ppm and with two probe lengths. The switch threshold and hysteresis can be set with potentiometers on the printed circuit board. The mounting flange included in the scope of supply facilitates installation in the ventilation ducts.
Datasheet
Description
EE85 is optimized for building automation as well as for process control applications. It measures CO2 concentration based on the Non-Dispersive Infrared (NDIR) technology. A patented autocalibration procedure compensates for the aging of the infrared source and leads to outstanding long-term stability. The air from the duct flows through the probe into the EE85 enclosure and back into the duct. Inside the enclosure the air diffuses through a membrane into the CO2 sensing cell. As there is no flow through the sensing cell, this is very well protected against dust. EE85 is available with measuring ranges of 0...2000, 0...5000 or 0...10000ppm and with two probe lengths. The switch threshold and hysteresis can be set with potentiometers on the printed circuit board. The mounting flange included in the scope of supply facilitates installation in the ventilation ducts.
Datasheet

Suppliers

Company
Product
Description
Supplier Links
Duct Mount CO<sub>2</sub> Switch - EE85 - E+E Elektronik
Engerwitzdorf, Austria
Duct Mount CO2 Switch
EE85
Duct Mount CO2 Switch EE85
EE85 is optimized for building automation as well as for process control applications. It measures CO2 concentration based on the Non-Dispersive Infrared (NDIR) technology. A patented autocalibration procedure compensates for the aging of the infrared source and leads to outstanding long-term stability. The air from the duct flows through the probe into the EE85 enclosure and back into the duct. Inside the enclosure the air diffuses through a membrane into the CO2 sensing cell. As there is no flow through the sensing cell, this is very well protected against dust. EE85 is available with measuring ranges of 0...2000, 0...5000 or 0...10000ppm and with two probe lengths. The switch threshold and hysteresis can be set with potentiometers on the printed circuit board. The mounting flange included in the scope of supply facilitates installation in the ventilation ducts.

EE85 is optimized for building automation as well as for process control applications. It measures CO2 concentration based on the Non-Dispersive Infrared (NDIR) technology.

A patented autocalibration procedure compensates for the aging of the infrared source and leads to outstanding long-term stability. The air from the duct flows through the probe into the EE85 enclosure and back into the duct. Inside the enclosure the air diffuses through a membrane into the CO2 sensing cell.

As there is no flow through the sensing cell, this is very well protected against dust. EE85 is available with measuring ranges of 0...2000, 0...5000 or 0...10000ppm and with two probe lengths.

The switch threshold and hysteresis can be set with potentiometers on the printed circuit board. The mounting flange included in the scope of supply facilitates installation in the ventilation ducts.

Supplier's Site Datasheet

Technical Specifications

  E+E Elektronik
Product Category Gas Instruments
Product Number EE85
Product Name Duct Mount CO2 Switch
Measurement Type Trace
Application Ambient Air Monitoring
Gas Types CO2; (0-2000 / 0-5000 / 0-10000 ppm)
Electrical Outputs Voltage; Current; Switch or Relay
Features Self Calibration
Unlock Full Specs
to access all available technical data

Similar Products

Carbon Dioxide Detection & Control Unit - CO2-2000 Series - Acme Engineering Products
Specs
Measurement Type Trace
Application Confined Space Entry
Gas Types Toxic; CO2; (0-5000 PPM)
View Details
Fixed Point Gas Detector - Vanguard WirelessHART® - United Electric Controls Company
Specs
Measurement Type %LEL or %LFL; Trace
Application Process Gas
Gas Types Toxic; Combustible; NH3; (0 - 100 ppm); CO; (0 - 500 ppm); H2S; (0 - 100 ppm); Methane (CH4) / Natural Gas; (0 to 100% LEL); (Propane (C3H8) 0 to 100% LEL)
View Details
Flue Gas Oxygen Analyzer - WDG 1210 - LAND
Specs
Measurement Type %Volume
Application Continuous Emissions Monitoring
Gas Types Toxic; O2; (From 0 to 1 %, 0 to 25 %)
View Details
Air Quality Monitors - 2121725 - RS Components, Ltd.
Specs
Operating Temperature 122 F (50 C)
Operating Humidity 90 %
View Details