Dynapar Corp. Industrial Duty Explosion-Proof Encoder Series X25

Description
Electrical outputs are electronically compatible with almost all drives and PLC's. Differential line driver outputs are available for long cable runs (hundreds of feet) and higher noise immunity.Series X25 encoders are designed for use in environments stated in: UL Class I, Group C: atmospheres such as ethyl ether and ethylene; UL Class I, Group D: atmospheres such as acetone, ammonia, benzene, butane, cyclopropane, ethanol, gasoline, hexane, methanol, methane, natural gas, naphtha, and propane; Class II, Groups E, F & G: combustible metal dusts, including aluminum, magnesium, and their commercial alloys, and atmospheres containing combustible carbonaceous dusts, including carbon black, charcoal, coal, or coke dusts, and combustible dusts including flour, grain, wood, plastic, and chemicals.Classifica tions of hazardous locations are subject to the approval of the authority having jurisdiction. Refer to Article 500 of the National Electrical Code (NEC).
Datasheet
Description
Electrical outputs are electronically compatible with almost all drives and PLC's. Differential line driver outputs are available for long cable runs (hundreds of feet) and higher noise immunity.Series X25 encoders are designed for use in environments stated in: UL Class I, Group C: atmospheres such as ethyl ether and ethylene; UL Class I, Group D: atmospheres such as acetone, ammonia, benzene, butane, cyclopropane, ethanol, gasoline, hexane, methanol, methane, natural gas, naphtha, and propane; Class II, Groups E, F & G: combustible metal dusts, including aluminum, magnesium, and their commercial alloys, and atmospheres containing combustible carbonaceous dusts, including carbon black, charcoal, coal, or coke dusts, and combustible dusts including flour, grain, wood, plastic, and chemicals.Classifica tions of hazardous locations are subject to the approval of the authority having jurisdiction. Refer to Article 500 of the National Electrical Code (NEC).
Datasheet

Suppliers

Company
Product
Description
Supplier Links
Industrial Duty Explosion-Proof Encoder - Series X25 - Dynapar Corp.
Gurnee, IL, USA
Industrial Duty Explosion-Proof Encoder
Series X25
Industrial Duty Explosion-Proof Encoder Series X25
Electrical outputs are electronically compatible with almost all drives and PLC's. Differential line driver outputs are available for long cable runs (hundreds of feet) and higher noise immunity.Series X25 encoders are designed for use in environments stated in: UL Class I, Group C: atmospheres such as ethyl ether and ethylene; UL Class I, Group D: atmospheres such as acetone, ammonia, benzene, butane, cyclopropane, ethanol, gasoline, hexane, methanol, methane, natural gas, naphtha, and propane; Class II, Groups E, F & G: combustible metal dusts, including aluminum, magnesium, and their commercial alloys, and atmospheres containing combustible carbonaceous dusts, including carbon black, charcoal, coal, or coke dusts, and combustible dusts including flour, grain, wood, plastic, and chemicals.Classifica tions of hazardous locations are subject to the approval of the authority having jurisdiction. Refer to Article 500 of the National Electrical Code (NEC).

Electrical outputs are electronically compatible with almost all drives and PLC's. Differential line driver outputs are available for long cable runs (hundreds of feet) and higher noise immunity.Series X25 encoders are designed for use in environments stated in: UL Class I, Group C: atmospheres such as ethyl ether and ethylene; UL Class I, Group D: atmospheres such as acetone, ammonia, benzene, butane, cyclopropane, ethanol, gasoline, hexane, methanol, methane, natural gas, naphtha, and propane; Class II, Groups E, F & G: combustible metal dusts, including aluminum, magnesium, and their commercial alloys, and atmospheres containing combustible carbonaceous dusts, including carbon black, charcoal, coal, or coke dusts, and combustible dusts including flour, grain, wood, plastic, and chemicals.Classifications of hazardous locations are subject to the approval of the authority having jurisdiction. Refer to Article 500 of the National Electrical Code (NEC).

Supplier's Site Datasheet

Technical Specifications

  Dynapar Corp.
Product Category Rotary Encoders
Product Number Series X25
Product Name Industrial Duty Explosion-Proof Encoder
Encoder Technology Optical
Encoder Type Incremental
Encoder Output Quadrature; Index (optional feature)
Output Signal Square Wave
Counts / Revolution 1 to 5000 (counts/revolution)
Unlock Full Specs
to access all available technical data

Similar Products

Hall Effect Encoder with Mechanical Detent - ESC17 - EBE Elektro-Bau-Elemente GmbH
Specs
Encoder Technology Mechanical
Operating Temperature -4 to 167 F (-20 to 75 C)
View Details
Specs
Encoder Technology Magnetic
Encoder Type Absolute; Incremental
View Details
Rotary Incremental Encoder - 9111S - Gurley Precision Instruments
Gurley Precision Instruments
Specs
Encoder Technology Optical
Encoder Type Incremental
Encoder Output Quadrature; Index
View Details
Encoders - DP09H2412B15F-ND - DigiKey
Specs
Encoder Type Incremental
Counts / Revolution 12 (counts/revolution)
Operating Temperature 14 to 149 F (-10 to 65 C)
View Details
2 suppliers