CSA Group Short-circuit temperature limits of electric cables with rated voltages of 1 kV (U m = 1,2 kV) and 3 kV (U m = 3,6 kV) IEC 60724:2000+AMD1:2008 CSV

Description
Gives guidance on the short-circuit maximum temperature limits of electric cables having rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV), with regard to the following: - insulating materials; - oversheath and bedding materials; - conductor and metallic sheath materials and methods of connection. The design and accessories and the influence of the installation conditions on the temperature limits are taken into consideration.
Description
Gives guidance on the short-circuit maximum temperature limits of electric cables having rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV), with regard to the following: - insulating materials; - oversheath and bedding materials; - conductor and metallic sheath materials and methods of connection. The design and accessories and the influence of the installation conditions on the temperature limits are taken into consideration.

Suppliers

Company
Product
Description
Supplier Links
Short-circuit temperature limits of electric cables with rated voltages of 1 kV (U m = 1,2 kV) and 3 kV (U m = 3,6 kV) - IEC 60724:2000+AMD1:2008 CSV - CSA Group
Toronto, Ontario, Canada
Short-circuit temperature limits of electric cables with rated voltages of 1 kV (U m = 1,2 kV) and 3 kV (U m = 3,6 kV)
IEC 60724:2000+AMD1:2008 CSV
Short-circuit temperature limits of electric cables with rated voltages of 1 kV (U m = 1,2 kV) and 3 kV (U m = 3,6 kV) IEC 60724:2000+AMD1:2008 CSV
Gives guidance on the short-circuit maximum temperature limits of electric cables having rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV), with regard to the following: - insulating materials; - oversheath and bedding materials; - conductor and metallic sheath materials and methods of connection. The design and accessories and the influence of the installation conditions on the temperature limits are taken into consideration.

Gives guidance on the short-circuit maximum temperature limits of electric cables having rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV), with regard to the following:
- insulating materials;
- oversheath and bedding materials;
- conductor and metallic sheath materials and methods of connection.
The design and accessories and the influence of the installation conditions on the temperature limits are taken into consideration.