Campbell Scientific, Inc. 5 V Analog Input Module CR9050

Description
The CR9050 is for use with the CR9000X-series or CR9000-series Measurement and Control Systems. The CR9050 has 14 differential or 28 single-ended inputs for measuring voltages up to ±5 V. An on-board PRT provides a reference temperature for thermocouple measurements, while a heavy copper grounding bar and connectors combine with the case design to reduce temperature gradients for accurate thermocouple measurements. Resolution on the most sensitive range is 1.6 microvolts. All input wires attach to the CR9050 via screw terminals.
Description
The CR9050 is for use with the CR9000X-series or CR9000-series Measurement and Control Systems. The CR9050 has 14 differential or 28 single-ended inputs for measuring voltages up to ±5 V. An on-board PRT provides a reference temperature for thermocouple measurements, while a heavy copper grounding bar and connectors combine with the case design to reduce temperature gradients for accurate thermocouple measurements. Resolution on the most sensitive range is 1.6 microvolts. All input wires attach to the CR9050 via screw terminals.

Suppliers

Company
Product
Description
Supplier Links
5 V Analog Input Module - CR9050 - Campbell Scientific, Inc.
Logan, UT, USA
5 V Analog Input Module
CR9050
5 V Analog Input Module CR9050
The CR9050 is for use with the CR9000X-series or CR9000-series Measurement and Control Systems. The CR9050 has 14 differential or 28 single-ended inputs for measuring voltages up to ±5 V. An on-board PRT provides a reference temperature for thermocouple measurements, while a heavy copper grounding bar and connectors combine with the case design to reduce temperature gradients for accurate thermocouple measurements. Resolution on the most sensitive range is 1.6 microvolts. All input wires attach to the CR9050 via screw terminals.

The CR9050 is for use with the CR9000X-series or CR9000-series Measurement and Control Systems. The CR9050 has 14 differential or 28 single-ended inputs for measuring voltages up to ±5 V. An on-board PRT provides a reference temperature for thermocouple measurements, while a heavy copper grounding bar and connectors combine with the case design to reduce temperature gradients for accurate thermocouple measurements. Resolution on the most sensitive range is 1.6 microvolts. All input wires attach to the CR9050 via screw terminals.

Supplier's Site

Technical Specifications

  Campbell Scientific, Inc.
Product Category Data Acquisition
Product Number CR9050
Product Name 5 V Analog Input Module
Data Acquisition Input Module
Form Factor PC Board
User Interface None
Host Connection Direct Backplane Interface
Application General Lab & Industrial
Unlock Full Specs
to access all available technical data