The VN2000 Hot Tap Insertion Vortex Flow Meter measures the volumetric or mass flow rate of steam, gases or liquids over a large flow range. The meter is a heavy duty design engineered to stand up to the most abusive environments inside and outside the pipe. Reliable, Easy to Install Hot Tap Insertion Meter. ideal for accurately measuring liquids, compressed air and saturated steam. No moving parts and virtually maintenance-free once installed. Removable Insertion/Extraction Tool. Aids in installation or removal in high pressure applications Reliable measurement for steam and a variety of fluids. Heavy duty design engineered to stand up to the most abusive environments inside and outside the pipe Reduced Maintenance Costs and Spare Parts. No internal o-rings or seals of any kind and absolutely no leak paths into the sensors or electronics. Our sensors do not touch the process fluid, which gives them an almost unlimited life span.
Datasheet
Description
The VN2000 Hot Tap Insertion Vortex Flow Meter measures the volumetric or mass flow rate of steam, gases or liquids over a large flow range. The meter is a heavy duty design engineered to stand up to the most abusive environments inside and outside the pipe. Reliable, Easy to Install Hot Tap Insertion Meter. ideal for accurately measuring liquids, compressed air and saturated steam. No moving parts and virtually maintenance-free once installed. Removable Insertion/Extraction Tool. Aids in installation or removal in high pressure applications Reliable measurement for steam and a variety of fluids. Heavy duty design engineered to stand up to the most abusive environments inside and outside the pipe Reduced Maintenance Costs and Spare Parts. No internal o-rings or seals of any kind and absolutely no leak paths into the sensors or electronics. Our sensors do not touch the process fluid, which gives them an almost unlimited life span.
Datasheet

Suppliers

Company
Product
Description
Supplier Links
VN2000 Hot Tap Insertion Flow Meter -  - Badger Meter
Milwaukee, WI, United States
VN2000 Hot Tap Insertion Flow Meter
VN2000 Hot Tap Insertion Flow Meter
The VN2000 Hot Tap Insertion Vortex Flow Meter measures the volumetric or mass flow rate of steam, gases or liquids over a large flow range. The meter is a heavy duty design engineered to stand up to the most abusive environments inside and outside the pipe. Reliable, Easy to Install Hot Tap Insertion Meter. ideal for accurately measuring liquids, compressed air and saturated steam. No moving parts and virtually maintenance-free once installed. Removable Insertion/Extraction Tool. Aids in installation or removal in high pressure applications Reliable measurement for steam and a variety of fluids. Heavy duty design engineered to stand up to the most abusive environments inside and outside the pipe Reduced Maintenance Costs and Spare Parts. No internal o-rings or seals of any kind and absolutely no leak paths into the sensors or electronics. Our sensors do not touch the process fluid, which gives them an almost unlimited life span.

The VN2000 Hot Tap Insertion Vortex Flow Meter measures the volumetric or mass flow rate of steam, gases or liquids over a large flow range. The meter is a heavy duty design engineered to stand up to the most abusive environments inside and outside the pipe.

Reliable, Easy to Install Hot Tap Insertion Meter.


ideal for accurately measuring liquids, compressed air and saturated steam. No moving parts and virtually maintenance-free once installed.

  • Removable Insertion/Extraction Tool. Aids in installation or removal in high pressure applications
  • Reliable measurement for steam and a variety of fluids. Heavy duty design engineered to stand up to the most abusive environments inside and outside the pipe
  • Reduced Maintenance Costs and Spare Parts. No internal o-rings or seals of any kind and absolutely no leak paths into the sensors or electronics. Our sensors do not touch the process fluid, which gives them an almost unlimited life span.
Supplier's Site Datasheet

Technical Specifications

  Badger Meter
Product Category Liquid Flow Meters
Product Name VN2000 Hot Tap Insertion Flow Meter
Operating Temperature -250 to 400 F (-157 to 204 C)
Process Media Type Liquid
Operating Pressure 0.0 to 1000 psi (0.0 to 704 m H2O)
Meter Type Mass Flow Meter
Mass Flow Rate 0.0287 to 346 lbs/min (7.80E-4 to 9.4 metric tons/hr)
Unlock Full Specs
to access all available technical data

Similar Products

Insertion Flow and Temperature Monitoring Switch - FlexSwitch® FLT93S - Fluid Components Intl. (FCI)
Specs
Meter Technology Thermal
Additional Variables Measured Temperature
Approvals ATEX; Canadian Standards Association; European Committee for Electrotechnical Standardization; FM, CE, NFPA Code 30 Compliance
View Details
Measurement - Flow - ultrasonic-Flow-meters - 159300316 - Georg Fischer Piping Systems Ltd
Specs
Meter Technology Ultrasonic
Process Media Type Liquid
Meter Type Volumetric Flow Meter
View Details
Process Cooling Water Stick - PCWR050BVS-PV - Plast-O-Matic Valves, Inc.
Specs
Additional Variables Measured Temperature (optional feature)
Process Media Type Liquid
Meter Type Volumetric Flow Meter
View Details
Ultrasonic Clamp-On Liquid Flow Meter - PanaFlow LC - Panametrics
Specs
Meter Technology Ultrasonic
Features Recorder / Totalizer Functions
Approvals ATEX