ASTM International Standard Test Method for Determination of Purity by Differential Scanning Calorimetry ASTM E928-01

Description
1.1 This test method covers the determination of purity by use of differential scanning calorimetry and the evaluation of the results using the van't Hoff equation. 1.2 This test method is generally applicable to thermally stable compounds with well-defined melting temperatures. 1.3 Determination of purity by this test method is only applicable when the impurity dissolves in the melt and is insoluble in the crystal. 1.4 Computer- or electronic-based instruments, techniques, or data treatments equivalent to this test method may also be used. Note 1--Since all data treatments are not equivalent, it is the responsibility of the user to verify equivalency prior to use. 1.5 SI values are the standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.6 There is no ISO method equivalent to this method.
Request a Quote
Description
1.1 This test method covers the determination of purity by use of differential scanning calorimetry and the evaluation of the results using the van't Hoff equation. 1.2 This test method is generally applicable to thermally stable compounds with well-defined melting temperatures. 1.3 Determination of purity by this test method is only applicable when the impurity dissolves in the melt and is insoluble in the crystal. 1.4 Computer- or electronic-based instruments, techniques, or data treatments equivalent to this test method may also be used. Note 1--Since all data treatments are not equivalent, it is the responsibility of the user to verify equivalency prior to use. 1.5 SI values are the standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.6 There is no ISO method equivalent to this method.
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Standard Test Method for Determination of Purity by Differential Scanning Calorimetry - ASTM E928-01 - ASTM International
West Conshohocken, PA, United States
Standard Test Method for Determination of Purity by Differential Scanning Calorimetry
ASTM E928-01
Standard Test Method for Determination of Purity by Differential Scanning Calorimetry ASTM E928-01
1.1 This test method covers the determination of purity by use of differential scanning calorimetry and the evaluation of the results using the van't Hoff equation. 1.2 This test method is generally applicable to thermally stable compounds with well-defined melting temperatures. 1.3 Determination of purity by this test method is only applicable when the impurity dissolves in the melt and is insoluble in the crystal. 1.4 Computer- or electronic-based instruments, techniques, or data treatments equivalent to this test method may also be used. Note 1--Since all data treatments are not equivalent, it is the responsibility of the user to verify equivalency prior to use. 1.5 SI values are the standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.6 There is no ISO method equivalent to this method.

1.1 This test method covers the determination of purity by use of differential scanning calorimetry and the evaluation of the results using the van't Hoff equation.

1.2 This test method is generally applicable to thermally stable compounds with well-defined melting temperatures.

1.3 Determination of purity by this test method is only applicable when the impurity dissolves in the melt and is insoluble in the crystal.

1.4 Computer- or electronic-based instruments, techniques, or data treatments equivalent to this test method may also be used.

Note 1--Since all data treatments are not equivalent, it is the responsibility of the user to verify equivalency prior to use.

1.5 SI values are the standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.6 There is no ISO method equivalent to this method.