Alfa Laval Inc. Heat Treatment Modules Thermolyser

Description
The Alfa Laval Thermolyser Core modules are specially designed to thermally deactivate spent brewer’s yeast by raising the yeast temperature above a pre-defined treatment threshold, and holding it at that exact temperature for the specified time.The deactivated yeast can then be used as an ingredient in other products, such as food supplements and animal feed, or safely disposed of safely. The Thermolyser module renders spent brewer’s yeast inactive by using a plate heat exchanger in tandem with a holding cell to heat the yeast in order to destroy the cell membranes. The incoming flow of cold yeast is heated to the target temperature for thermolysation in two steps, using a high-efficiency Alfa Laval plate heat exchanger. The yeast is first heated in the heat recovery section, where it circulates against already thermolysed yeast, and then in a heating section, in which circulating hot water is used to bring the yeast to the specified holding temperature. The module is can be configured for a wide range of capacities, from below 25 hl/h to over 100 hl/h, and can be outfitted with several options, including a longer thermolysation holding time, increased energy recovery, cooling of the thermolysed yeast, steam pressure regulation and valve position feedback, among others.
Description
The Alfa Laval Thermolyser Core modules are specially designed to thermally deactivate spent brewer’s yeast by raising the yeast temperature above a pre-defined treatment threshold, and holding it at that exact temperature for the specified time.The deactivated yeast can then be used as an ingredient in other products, such as food supplements and animal feed, or safely disposed of safely. The Thermolyser module renders spent brewer’s yeast inactive by using a plate heat exchanger in tandem with a holding cell to heat the yeast in order to destroy the cell membranes. The incoming flow of cold yeast is heated to the target temperature for thermolysation in two steps, using a high-efficiency Alfa Laval plate heat exchanger. The yeast is first heated in the heat recovery section, where it circulates against already thermolysed yeast, and then in a heating section, in which circulating hot water is used to bring the yeast to the specified holding temperature. The module is can be configured for a wide range of capacities, from below 25 hl/h to over 100 hl/h, and can be outfitted with several options, including a longer thermolysation holding time, increased energy recovery, cooling of the thermolysed yeast, steam pressure regulation and valve position feedback, among others.

Suppliers

Company
Product
Description
Supplier Links
Heat Treatment Modules - Thermolyser - Alfa Laval Inc.
Scarborough, Ontario, Canada
Heat Treatment Modules
Thermolyser
Heat Treatment Modules Thermolyser
The Alfa Laval Thermolyser Core modules are specially designed to thermally deactivate spent brewer’s yeast by raising the yeast temperature above a pre-defined treatment threshold, and holding it at that exact temperature for the specified time.The deactivated yeast can then be used as an ingredient in other products, such as food supplements and animal feed, or safely disposed of safely. The Thermolyser module renders spent brewer’s yeast inactive by using a plate heat exchanger in tandem with a holding cell to heat the yeast in order to destroy the cell membranes. The incoming flow of cold yeast is heated to the target temperature for thermolysation in two steps, using a high-efficiency Alfa Laval plate heat exchanger. The yeast is first heated in the heat recovery section, where it circulates against already thermolysed yeast, and then in a heating section, in which circulating hot water is used to bring the yeast to the specified holding temperature. The module is can be configured for a wide range of capacities, from below 25 hl/h to over 100 hl/h, and can be outfitted with several options, including a longer thermolysation holding time, increased energy recovery, cooling of the thermolysed yeast, steam pressure regulation and valve position feedback, among others.

The Alfa Laval Thermolyser Core modules are specially designed to thermally deactivate spent brewer’s yeast by raising the yeast temperature above a pre-defined treatment threshold, and holding it at that exact temperature for the specified time.The deactivated yeast can then be used as an ingredient in other products, such as food supplements and animal feed, or safely disposed of safely.


The Thermolyser module renders spent brewer’s yeast inactive by using a plate heat exchanger in tandem with a holding cell to heat the yeast in order to destroy the cell membranes.

The incoming flow of cold yeast is heated to the target temperature for thermolysation in two steps, using a high-efficiency Alfa Laval plate heat exchanger. The yeast is first heated in the heat recovery section, where it circulates against already thermolysed yeast, and then in a heating section, in which circulating hot water is used to bring the yeast to the specified holding temperature.

The module is can be configured for a wide range of capacities, from below 25 hl/h to over 100 hl/h, and can be outfitted with several options, including a longer thermolysation holding time, increased energy recovery, cooling of the thermolysed yeast, steam pressure regulation and valve position feedback, among others.

Supplier's Site

Technical Specifications

  Alfa Laval Inc.
Product Category Heat Exchangers
Product Number Thermolyser
Product Name Heat Treatment Modules
Application / Industry Food or Beverage Processing
Unlock Full Specs
to access all available technical data

Similar Products

Plate Heat Exchangers - 1891661 - RS Components, Ltd.
Specs
Technology Plate
Primary Material Copper or Copper Alloy
Number of Tubes / Plates / Fans 1
View Details
AdvancAir -  - Air Innovations LLC
Air Innovations LLC
Specs
Application / Industry Aerospace / Aviation; Chemical Processing; Food or Beverage Processing; HVAC; Marine; Oil Heating / Cooling; Custom
Technology Air-Cooled; Water-Cooled
Temperature Range 0 to 100 F (-18 to 38 C)
View Details
Water-to-Air Heat Exchanger -  - Ambrell Induction Heating Solutions
Ambrell Induction Heating Solutions
Specs
Technology Air-Cooled
Type Electric Fan
Working Pressure 45 psi (31.67 m H2O)
View Details
Oil-air Cooler - DCN - jbj Techniques Limited
jbj Techniques Limited
Specs
Application / Industry Oil Heating / Cooling
Technology Air-Cooled
Type Electric Fan
View Details