ABB Measurement & Analytics Laboratory Spectrometer MB3600-CH10

Description
The IV determination uses a global calibration in accordance with the AOCS-approved standard procedure Cd 1e_01. This global IV calibration is based on a wide selection of oils and fats obtained from multiple production facilities worldwide. The %Trans determination uses a global calibration based on a similarly wide range of oils. ABB’s world-renowned range of on-line and laboratory FT-NIR analyzers provide guaranteed transferability of calibration models between laboratory and process applications. The accuracy and reliability of the FT-NIR based method has been evaluated via an official AOCS-supervised round robin test. Because of the inherent high reproducibility and stability of ABB’s FT-NIR analyzer technology, the analysis procedure is universally applicable to a wide variety of oils and fats without any calibration adjustments.
Request a Quote Datasheet
Description
The IV determination uses a global calibration in accordance with the AOCS-approved standard procedure Cd 1e_01. This global IV calibration is based on a wide selection of oils and fats obtained from multiple production facilities worldwide. The %Trans determination uses a global calibration based on a similarly wide range of oils. ABB’s world-renowned range of on-line and laboratory FT-NIR analyzers provide guaranteed transferability of calibration models between laboratory and process applications. The accuracy and reliability of the FT-NIR based method has been evaluated via an official AOCS-supervised round robin test. Because of the inherent high reproducibility and stability of ABB’s FT-NIR analyzer technology, the analysis procedure is universally applicable to a wide variety of oils and fats without any calibration adjustments.
Request a Quote Datasheet

Suppliers

Company
Product
Description
Supplier Links
Laboratory Spectrometer - MB3600-CH10 - ABB Measurement & Analytics
Zurich, Switzerland
Laboratory Spectrometer
MB3600-CH10
Laboratory Spectrometer MB3600-CH10
The IV determination uses a global calibration in accordance with the AOCS-approved standard procedure Cd 1e_01. This global IV calibration is based on a wide selection of oils and fats obtained from multiple production facilities worldwide. The %Trans determination uses a global calibration based on a similarly wide range of oils. ABB’s world-renowned range of on-line and laboratory FT-NIR analyzers provide guaranteed transferability of calibration models between laboratory and process applications. The accuracy and reliability of the FT-NIR based method has been evaluated via an official AOCS-supervised round robin test. Because of the inherent high reproducibility and stability of ABB’s FT-NIR analyzer technology, the analysis procedure is universally applicable to a wide variety of oils and fats without any calibration adjustments.

The IV determination uses a global calibration in accordance with the AOCS-approved standard procedure Cd 1e_01. This global IV calibration is based on a wide selection of oils and fats obtained from multiple production facilities worldwide.

The %Trans determination uses a global calibration based on a similarly wide range of oils. ABB’s world-renowned range of on-line and laboratory FT-NIR analyzers provide guaranteed transferability of calibration models between laboratory and process applications.

The accuracy and reliability of the FT-NIR based method has been evaluated via an official AOCS-supervised round robin test. Because of the inherent high reproducibility and stability of ABB’s FT-NIR analyzer technology, the analysis procedure is universally applicable to a wide variety of oils and fats without any calibration adjustments.

Supplier's Site Datasheet

Technical Specifications

  ABB Measurement & Analytics
Product Category Infrared Spectrometers
Product Number MB3600-CH10
Product Name Laboratory Spectrometer
Measurement Type Fourier Transform Infrared
Unlock Full Specs
to access all available technical data

Similar Products

Fully Integrated Multi-channel fibre-optic FT-NIR analyzer in Ex enclosure - FTPA2000- HP260X - ABB Measurement & Analytics
Specs
Features Cooled Detector; Hazardous Environment
View Details
FT-NIR solids analyzer - MB3600-CH40 - ABB Measurement & Analytics
ABB Measurement & Analytics
Specs
Optical System Michelson Interferometer
Detector Type Other; (Detector module with integrated cooling: extended-InGaAs)
Sample Type Solids
View Details
Laboratory Spectrometer - MB3600-CH30 - ABB Measurement & Analytics
ABB Measurement & Analytics
Specs
Measurement Type Fourier Transform Infrared
Sample Type Gases
Display Video
View Details
Laboratory Spectrometer - MB3600 - ABB Measurement & Analytics
ABB Measurement & Analytics
Specs
Measurement Type Fourier Transform Infrared
Detector Type DTGS; Other
Sample Type Gases
View Details