Maury mismatch airlines have been designed as verification standards to be used in VNA calibration validation. Each mismatch airline is provided with factory S-parameters data that can be compared with user-measured S-parameters for VNA calibration validation. Measurement uncertainty is also provided, and uncertainty boundaries can be used for definitive calibration validation when used in conjunction with MT940B Insight Real-Time Uncertainty Add-On.
Request a Quote
Description
Maury mismatch airlines have been designed as verification standards to be used in VNA calibration validation. Each mismatch airline is provided with factory S-parameters data that can be compared with user-measured S-parameters for VNA calibration validation. Measurement uncertainty is also provided, and uncertainty boundaries can be used for definitive calibration validation when used in conjunction with MT940B Insight Real-Time Uncertainty Add-On.
Request a Quote
Datasheet
Datasheet Summary
Powered by GS/AI

The 2603F75 is a VNA calibration verification standard with a Type N connector, operating from DC to 18.0 GHz, with an electrical length of 6.604 cm and a nominal impedance of 75 Ω, and an electrical length accuracy of ±0.02 cm.

Datasheet Summary
Powered by GS/AI

The 2603F75 is a VNA calibration verification standard with a Type N connector, operating from DC to 18.0 GHz, with an electrical length of 6.604 cm and a nominal impedance of 75 Ω, and an electrical length accuracy of ±0.02 cm.

Suppliers

Company
Product
Description
Supplier Links
VNA Calibration Standard - 2603F75 - Maury Microwave
Ontario, CA, United States
VNA Calibration Standard
2603F75
VNA Calibration Standard 2603F75
Maury mismatch airlines have been designed as verification standards to be used in VNA calibration validation. Each mismatch airline is provided with factory S-parameters data that can be compared with user-measured S-parameters for VNA calibration validation. Measurement uncertainty is also provided, and uncertainty boundaries can be used for definitive calibration validation when used in conjunction with MT940B Insight Real-Time Uncertainty Add-On.

Maury mismatch airlines have been designed as verification standards to be used in VNA calibration validation. Each mismatch airline is provided with factory S-parameters data that can be compared with user-measured S-parameters for VNA calibration validation. Measurement uncertainty is also provided, and uncertainty boundaries can be used for definitive calibration validation when used in conjunction with MT940B Insight Real-Time Uncertainty Add-On.

Supplier's Site Datasheet

Technical Specifications

  Maury Microwave
Product Category Calibration Instruments
Product Number 2603F75
Product Name VNA Calibration Standard
Calibration Signal Signal / Waveform Generator Output
Unlock Full Specs
to access all available technical data

Similar Products

Manual Tuner - MST984A24 - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 5.00E10 Hz
Electrical Properties Resistance/ Impedance
View Details
VNA Calibration Standard - 2611C - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 1.80E10 Hz
Electrical Properties Resistance/ Impedance
View Details
VNA Calibration Standard - 2553T3.12 - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 1.80E10 Hz
Electrical Properties Resistance/ Impedance
View Details
Automated Tuner - MT979AL - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 1.10E11 Hz
Electrical Properties Resistance/ Impedance
View Details