Protection of humans and machines in accordance with: EC Directive on Machines 89/392/EEC, IEC 204, EN 60204, DIN VDE 0113
Machine emergency stop switches. Monitors safety doors. SK 3 (with equivalent switching). Output: 3 N/Os, 1 N/C for AC 380 V. 1 or 2-channel configuration. LED indicators for channels 1 and 2. Control loop X3-X4 for monitoring external protection. Removable terminals
Supply Voltage = 24 V dc
Number of Channels = 2
Auxiliary Contacts = 1
Function = Emergency Stop
Safety Category ISO 13849-1 = 4
SIL IEC 61508 = 3
PL ISO 13849-1 = E
Safety Contacts = 3
Range = Safemaster
Reset Method = Monitored