AccuRate/Schenck AccuRate Multicor® Mass Flow Meter S40

Description
The Multicor® mass flow meter line uses the science of particle acceleration and its resultant forces to measure flow rate and total weight at accuracies of +/- 0.5%. Space efficiency and overall reliability make Multicor® an ideal choice for feeding, measuring and batching applications involving reasonably free-flowing dry materials. Multicor® consists of a partitioned measuring wheel, mounted on a drive shaft inside a central dust tight housing. The drive shaft is driven by an electric motor mounted outside Multicor®'s housing. Material enters the unit through an off-center inlet and discharges through a center outlet below the measuring wheel.In operation, the measuring wheel rotates at a constant speed. Material entering the unit flows into the top of the measuring wheel and is deflected outward in a radial direction creating a "Coriolis force". Multicor® sees this force as a change in torque which is detected by a strain gauge load cell. The output of the load cell is electronically processed to produce flow rate and total weight values at accuracies of +/- 0.5%. Best of all, unlike other flow meters on the market, Multicor®'s performance is not affected by material density, friction or in-feed drop height.
Description
The Multicor® mass flow meter line uses the science of particle acceleration and its resultant forces to measure flow rate and total weight at accuracies of +/- 0.5%. Space efficiency and overall reliability make Multicor® an ideal choice for feeding, measuring and batching applications involving reasonably free-flowing dry materials. Multicor® consists of a partitioned measuring wheel, mounted on a drive shaft inside a central dust tight housing. The drive shaft is driven by an electric motor mounted outside Multicor®'s housing. Material enters the unit through an off-center inlet and discharges through a center outlet below the measuring wheel.In operation, the measuring wheel rotates at a constant speed. Material entering the unit flows into the top of the measuring wheel and is deflected outward in a radial direction creating a "Coriolis force". Multicor® sees this force as a change in torque which is detected by a strain gauge load cell. The output of the load cell is electronically processed to produce flow rate and total weight values at accuracies of +/- 0.5%. Best of all, unlike other flow meters on the market, Multicor®'s performance is not affected by material density, friction or in-feed drop height.

Suppliers

Company
Product
Description
Supplier Links
Multicor® Mass Flow Meter - S40 - AccuRate/Schenck AccuRate
Whitewater, WI, USA
Multicor® Mass Flow Meter
S40
Multicor® Mass Flow Meter S40
The Multicor® mass flow meter line uses the science of particle acceleration and its resultant forces to measure flow rate and total weight at accuracies of +/- 0.5%. Space efficiency and overall reliability make Multicor® an ideal choice for feeding, measuring and batching applications involving reasonably free-flowing dry materials. Multicor® consists of a partitioned measuring wheel, mounted on a drive shaft inside a central dust tight housing. The drive shaft is driven by an electric motor mounted outside Multicor®'s housing. Material enters the unit through an off-center inlet and discharges through a center outlet below the measuring wheel.In operation, the measuring wheel rotates at a constant speed. Material entering the unit flows into the top of the measuring wheel and is deflected outward in a radial direction creating a "Coriolis force". Multicor® sees this force as a change in torque which is detected by a strain gauge load cell. The output of the load cell is electronically processed to produce flow rate and total weight values at accuracies of +/- 0.5%. Best of all, unlike other flow meters on the market, Multicor®'s performance is not affected by material density, friction or in-feed drop height.

The Multicor® mass flow meter line uses the science of particle acceleration and its resultant forces to measure flow rate and total weight at accuracies of +/- 0.5%. Space efficiency and overall reliability make Multicor® an ideal choice for feeding, measuring and batching applications involving reasonably free-flowing dry materials.
Multicor® consists of a partitioned measuring wheel, mounted on a drive shaft inside a central dust tight housing. The drive shaft is driven by an electric motor mounted outside Multicor®'s housing. Material enters the unit through an off-center inlet and discharges through a center outlet below the measuring wheel.In operation, the measuring wheel rotates at a constant speed. Material entering the unit flows into the top of the measuring wheel and is deflected outward in a radial direction creating a "Coriolis force". Multicor® sees this force as a change in torque which is detected by a strain gauge load cell. The output of the load cell is electronically processed to produce flow rate and total weight values at accuracies of +/- 0.5%. Best of all, unlike other flow meters on the market, Multicor®'s performance is not affected by material density, friction or in-feed drop height.

Supplier's Site

Technical Specifications

  AccuRate/Schenck AccuRate
Product Category Solids Flow Meters
Product Number S40
Product Name Multicor® Mass Flow Meter
Unlock Full Specs
to access all available technical data

Similar Products