Bio-Rad Laboratories, Inc. Immun-Blot Goat Anti-Human IgG (H + L)-HRP Assay Kit 170-6465

Description
Colorimetric immunodetection kit, includes 4CN, horseradish peroxidase secondary antibody conjugate, 10x TBS, Tween 20, gelatin; for 200 assays Enzymes such as HRP or AP convert several substrates to a colored precipitate. As the precipitate accumulates on the blot, a colored signal develops. The reaction can be monitored and stopped when the desired signal over background is observed. Colorimetric detection is easier to perform than film-based chemiluminescence detection; however, the method's single endpoint result does not allow the multiple exposures of chemiluminescence methods. Colorimetric detection is typically considered a medium-sensitivity method compared to radioactive or chemiluminescence detection. Bio-Rad's HRP-based colorimetric detection systems offer a choice of HRP-conjugated secondary antibodies and HRP-conjugated protein A or protein G using the detection reagent 4-chloro-1-naphthol( 4CN). Bio-Rad offers three types of kits based on this chemistry for colorimetric HRP detection; individual reagents are also available, including 3,3'-diaminobenzidin e (DAB), an alternative reagent.
Description
Colorimetric immunodetection kit, includes 4CN, horseradish peroxidase secondary antibody conjugate, 10x TBS, Tween 20, gelatin; for 200 assays Enzymes such as HRP or AP convert several substrates to a colored precipitate. As the precipitate accumulates on the blot, a colored signal develops. The reaction can be monitored and stopped when the desired signal over background is observed. Colorimetric detection is easier to perform than film-based chemiluminescence detection; however, the method's single endpoint result does not allow the multiple exposures of chemiluminescence methods. Colorimetric detection is typically considered a medium-sensitivity method compared to radioactive or chemiluminescence detection. Bio-Rad's HRP-based colorimetric detection systems offer a choice of HRP-conjugated secondary antibodies and HRP-conjugated protein A or protein G using the detection reagent 4-chloro-1-naphthol( 4CN). Bio-Rad offers three types of kits based on this chemistry for colorimetric HRP detection; individual reagents are also available, including 3,3'-diaminobenzidin e (DAB), an alternative reagent.

Suppliers

Company
Product
Description
Supplier Links
Immun-Blot Goat Anti-Human IgG (H + L)-HRP Assay Kit - 170-6465 - Bio-Rad Laboratories, Inc.
Hercules, CA, USA
Immun-Blot Goat Anti-Human IgG (H + L)-HRP Assay Kit
170-6465
Immun-Blot Goat Anti-Human IgG (H + L)-HRP Assay Kit 170-6465
Colorimetric immunodetection kit, includes 4CN, horseradish peroxidase secondary antibody conjugate, 10x TBS, Tween 20, gelatin; for 200 assays Enzymes such as HRP or AP convert several substrates to a colored precipitate. As the precipitate accumulates on the blot, a colored signal develops. The reaction can be monitored and stopped when the desired signal over background is observed. Colorimetric detection is easier to perform than film-based chemiluminescence detection; however, the method's single endpoint result does not allow the multiple exposures of chemiluminescence methods. Colorimetric detection is typically considered a medium-sensitivity method compared to radioactive or chemiluminescence detection. Bio-Rad's HRP-based colorimetric detection systems offer a choice of HRP-conjugated secondary antibodies and HRP-conjugated protein A or protein G using the detection reagent 4-chloro-1-naphthol( 4CN). Bio-Rad offers three types of kits based on this chemistry for colorimetric HRP detection; individual reagents are also available, including 3,3'-diaminobenzidin e (DAB), an alternative reagent.

Colorimetric immunodetection kit, includes 4CN, horseradish peroxidase secondary antibody conjugate, 10x TBS, Tween 20, gelatin; for 200 assays

Enzymes such as HRP or AP convert several substrates to a colored precipitate. As the precipitate accumulates on the blot, a colored signal develops. The reaction can be monitored and stopped when the desired signal over background is observed. Colorimetric detection is easier to perform than film-based chemiluminescence detection; however, the method's single endpoint result does not allow the multiple exposures of chemiluminescence methods. Colorimetric detection is typically considered a medium-sensitivity method compared to radioactive or chemiluminescence detection.

Bio-Rad's HRP-based colorimetric detection systems offer a choice of HRP-conjugated secondary antibodies and HRP-conjugated protein A or protein G using the detection reagent 4-chloro-1-naphthol(4CN). Bio-Rad offers three types of kits based on this chemistry for colorimetric HRP detection; individual reagents are also available, including 3,3'-diaminobenzidine (DAB), an alternative reagent.

Supplier's Site

Technical Specifications

  Bio-Rad Laboratories, Inc.
Product Category Organic Chemicals
Product Number 170-6465
Product Name Immun-Blot Goat Anti-Human IgG (H + L)-HRP Assay Kit
Trigger Base
Unlock Full Specs
to access all available technical data

Similar Products

DMI 1,3 Dimethyl-2-Imidazolidinone -  - Mitsui Chemicals America, Inc.
Mitsui Chemicals America, Inc.
Specs
Trigger Solvent
Chemical Name DMI 1,3 Dimethyl-2-Imidazolidinone
State of Matter Liquid / Solution
View Details
AsahiKlin Precision Cleaning Solvent - AE3000 - AGC Chemicals Americas, Inc.
Specs
Trigger Solvent
Chemical Family All Halogenated; All Ethers
Chemical Name 1,1,2,2-tetra fluoroethyl-2,2,2-trifluoromethyl ether
View Details
3-Amino-imidazo[1,2-a]pyridine - A611725 - Toronto Research Chemicals, Inc.
Toronto Research Chemicals, Inc.
Specs
Chemical Name 3-Amino-imidazo[1,2-a]pyridine
Chemical Formula C7H7N3
CAS Number 28036-33-1
View Details