BARTEC APEXmpc / SILASmpc apexmpc-silasmpc

Description
The Ex p control unit APEXmpc controls and monitors the purge and operating phase of pressurized motors which are protected according to ignition protection type pxb. The parameters are set via the integrated WEB interface or the optionally available p operator panel. The APEXmpc has two enable relays, one with voltage and one with potential-free contacts. In addition, 2 signal relays with one changeover contact each are available. Three PT100/1000 inputs are available for temperature monitoring of the Ex p protected equipment. These can be assigned up to 3 switching values. In APEXmpc all necessary components for setting up the Ex pxb monitoring and purging gas valves are integrated. In addition, the following components are required for setting up an overall control system: - Outlet "Motor Purge Valve - mpv". - Optionally, a p operator panel can be connected The Ex p control unit SILASmpc is the equivalent Ex p control unit for zone 2/22.
Request a Quote
Description
The Ex p control unit APEXmpc controls and monitors the purge and operating phase of pressurized motors which are protected according to ignition protection type pxb. The parameters are set via the integrated WEB interface or the optionally available p operator panel. The APEXmpc has two enable relays, one with voltage and one with potential-free contacts. In addition, 2 signal relays with one changeover contact each are available. Three PT100/1000 inputs are available for temperature monitoring of the Ex p protected equipment. These can be assigned up to 3 switching values. In APEXmpc all necessary components for setting up the Ex pxb monitoring and purging gas valves are integrated. In addition, the following components are required for setting up an overall control system: - Outlet "Motor Purge Valve - mpv". - Optionally, a p operator panel can be connected The Ex p control unit SILASmpc is the equivalent Ex p control unit for zone 2/22.
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
APEXmpc / SILASmpc - apexmpc-silasmpc - BARTEC
Bad Mergentheim, Germany
APEXmpc / SILASmpc
apexmpc-silasmpc
APEXmpc / SILASmpc apexmpc-silasmpc
The Ex p control unit APEXmpc controls and monitors the purge and operating phase of pressurized motors which are protected according to ignition protection type pxb. The parameters are set via the integrated WEB interface or the optionally available p operator panel. The APEXmpc has two enable relays, one with voltage and one with potential-free contacts. In addition, 2 signal relays with one changeover contact each are available. Three PT100/1000 inputs are available for temperature monitoring of the Ex p protected equipment. These can be assigned up to 3 switching values. In APEXmpc all necessary components for setting up the Ex pxb monitoring and purging gas valves are integrated. In addition, the following components are required for setting up an overall control system: - Outlet "Motor Purge Valve - mpv". - Optionally, a p operator panel can be connected The Ex p control unit SILASmpc is the equivalent Ex p control unit for zone 2/22.

The Ex p control unit APEXmpc controls and monitors the purge and operating phase of pressurized motors which are protected according to ignition protection type pxb.

The parameters are set via the integrated WEB interface or the optionally available p operator panel. The APEXmpc has two enable relays, one with voltage and one with potential-free contacts. In addition, 2 signal relays with one changeover contact each are available.

Three PT100/1000 inputs are available for temperature monitoring of the Ex p protected equipment. These can be assigned up to 3 switching values.

In APEXmpc all necessary components for setting up the Ex pxb monitoring and purging gas valves are integrated.

In addition, the following components are required for setting up an overall control system:
- Outlet "Motor Purge Valve - mpv".
- Optionally, a p operator panel can be connected
The Ex p control unit SILASmpc is the equivalent Ex p control unit for zone 2/22.

Supplier's Site

Technical Specifications

  BARTEC
Product Category Control Panels
Product Number apexmpc-silasmpc
Product Name APEXmpc / SILASmpc
Panel Operation Electrical
Unlock Full Specs
to access all available technical data

Similar Products

p Operator Panel - p-operator-panel - BARTEC
Specs
Operating Temperature -25 to 50 F (-31.67 to 10 C)
View Details
APEXpy - apexpy - BARTEC
Specs
Panel Operation Electrical
Display Type

6 LEDs for status display

Voltage 230 volts
View Details
Local control stations - local control stations a7 3 zone 2 - BARTEC
Specs
Panel Operation Electrical
Current 160 amps
Voltage 1000 volts
View Details