This XC Unit was one of four built in Sept 2005 for a Critical Care Hospital in Ontario. It provides 25,277 supply and return air cfm and features a large Model XLTâ„¢ 80â€"84 flat plate aluminum air-to-air heat exchanger, cabinet, face-and-bypass frost control, and filters. The exchanger recovers 1,315 MBH at winterdesign conditions raising the outside air to 46oF. At summer design conditions, it recovers 280 MBH lowering the outside air temp to 85 oF.
Description
This XC Unit was one of four built in Sept 2005 for a Critical Care Hospital in Ontario. It provides 25,277 supply and return air cfm and features a large Model XLTâ„¢ 80â€"84 flat plate aluminum air-to-air heat exchanger, cabinet, face-and-bypass frost control, and filters. The exchanger recovers 1,315 MBH at winterdesign conditions raising the outside air to 46oF. At summer design conditions, it recovers 280 MBH lowering the outside air temp to 85 oF.

Suppliers

Company
Product
Description
Supplier Links
High Volume Energy Recovery for a Hospital - XC-80-84-BP-RT - XeteX, Inc.
Minneapolis, MN, USA
High Volume Energy Recovery for a Hospital
XC-80-84-BP-RT
High Volume Energy Recovery for a Hospital XC-80-84-BP-RT
This XC Unit was one of four built in Sept 2005 for a Critical Care Hospital in Ontario. It provides 25,277 supply and return air cfm and features a large Model XLTâ„¢ 80â€"84 flat plate aluminum air-to-air heat exchanger, cabinet, face-and-bypass frost control, and filters. The exchanger recovers 1,315 MBH at winterdesign conditions raising the outside air to 46oF. At summer design conditions, it recovers 280 MBH lowering the outside air temp to 85 oF.

This XC Unit was one of four built in Sept 2005 for a Critical Care Hospital in Ontario. It provides 25,277 supply and return air cfm and features a large Model XLTâ„¢ 80â€"84 flat plate aluminum air-to-air heat exchanger, cabinet, face-and-bypass frost control, and filters. The exchanger recovers 1,315 MBH at winterdesign conditions raising the outside air to 46oF. At summer design conditions, it recovers 280 MBH lowering the outside air temp to 85 oF.

Supplier's Site

Technical Specifications

  XeteX, Inc.
Product Category Heat and Energy Recovery Systems
Product Number XC-80-84-BP-RT
Product Name High Volume Energy Recovery for a Hospital
Application Residential
Unlock Full Specs
to access all available technical data

Similar Products

AdvancAir -  - Air Innovations LLC
Air Innovations LLC
Specs
Application Industrial
System Air to Air Heat Exchanger
View Details
Energy Recovery Ventilator (500 to 10,000 cfm) - ERV - Loren Cook Company
Specs
Application Commercial; Industrial
System Air to Air Heat Exchanger
View Details
Specs
Application Commercial
System Exhaust /Flue Heat Recovery; Heat Recovery Ventilator (ERV)
View Details
Heat Revovery System - S-energy® EES - Sullair Corporation
Specs
Application Industrial
System Air to Air Heat Exchanger; Heat Energy Recovery
View Details