Watts Ductile Iron Single Chamber Pump Control Valve with Backpressure Feature 982GD

Description
Designed to minimize the surges associated with the starting and stopping of pumps, and automatically throttle when pump discharge pressure falls below an adjustable minimum, increasing backpressure against the pump. The valve opens at an adjustable rate upon pump start-up, and closes at an adjustable rate upon pump shut-off. When the valve is near closed the limit switch is tripped, turning the pump off. The pump starts and stops against a closed valve. The Solenoid Pilot has provisions for manual operation in the event of power outage.
Datasheet
Description
Designed to minimize the surges associated with the starting and stopping of pumps, and automatically throttle when pump discharge pressure falls below an adjustable minimum, increasing backpressure against the pump. The valve opens at an adjustable rate upon pump start-up, and closes at an adjustable rate upon pump shut-off. When the valve is near closed the limit switch is tripped, turning the pump off. The pump starts and stops against a closed valve. The Solenoid Pilot has provisions for manual operation in the event of power outage.
Datasheet

Suppliers

Company
Product
Description
Supplier Links
Ductile Iron Single Chamber Pump Control Valve with Backpressure Feature - 982GD - Watts
North Andover, MA, USA
Ductile Iron Single Chamber Pump Control Valve with Backpressure Feature
982GD
Ductile Iron Single Chamber Pump Control Valve with Backpressure Feature 982GD
Designed to minimize the surges associated with the starting and stopping of pumps, and automatically throttle when pump discharge pressure falls below an adjustable minimum, increasing backpressure against the pump. The valve opens at an adjustable rate upon pump start-up, and closes at an adjustable rate upon pump shut-off. When the valve is near closed the limit switch is tripped, turning the pump off. The pump starts and stops against a closed valve. The Solenoid Pilot has provisions for manual operation in the event of power outage.

Designed to minimize the surges associated with the starting and stopping of pumps, and automatically throttle when pump discharge pressure falls below an adjustable minimum, increasing backpressure against the pump. The valve opens at an adjustable rate upon pump start-up, and closes at an adjustable rate upon pump shut-off. When the valve is near closed the limit switch is tripped, turning the pump off. The pump starts and stops against a closed valve. The Solenoid Pilot has provisions for manual operation in the event of power outage.

Supplier's Site Datasheet

Technical Specifications

  Watts
Product Category Industrial Valves
Product Number 982GD
Product Name Ductile Iron Single Chamber Pump Control Valve with Backpressure Feature
Valve Type Control Valve
Unlock Full Specs
to access all available technical data

Similar Products

Needle Valves, Tube -  - Haskel International LLC
Haskel International LLC
Specs
Valve Type Needle
Media Gas; Air; Compressed Air
Actuation Manual
View Details
3 in. Size Foot Valve|Master File - FV300 - Kuriyama of America, Inc.
Specs
Valve Type Foot Valve
Primary Material Cast Iron
Valve Size 3.00 inch (76.20 mm)
View Details
High-Pressure Control Valve -  - Shanghai Thinktank Process Management Co., Ltd
Shanghai Thinktank Process Management Co., Ltd
Specs
Valve Type Control Valve; Directional; Globe
Media Steam
View Details
ASOV air shut off valves -  - jbj Techniques Limited
jbj Techniques Limited
Specs
Valve Type Shut Off; Special guillotine-design (Swing Valve)
Media Air
Valve Size 2.00 to 13.00 inch (50.80 to 330.20 mm)
View Details