Det-Tronics Toxic Gas Detector GT3000

Description
The Det-Tronics GT3000 line of electrochemical fixed-point toxic-gas detectors provides continuous monitoring of the atmosphere for potentially hazardous toxic gas leaks or oxygen depletion. The GT3000 family currently includes sensors that detect each of the following gases (additional gases added soon): hydrogen sulfide (H2S) hydrogen (H2) oxygen (O2) carbon monoxide (CO) nitrogen dioxide (NO2) ammonia (NH3) chlorine (Cl2) sulfur dioxide (SO2) A complete GT3000 detector consists of a transmitter (GTX) and a sensor module (GTS). The transmitter generates a 4-20 mA output signal with HART that is proportional to the concentration of the target gas and corresponds directly to 0-100% full scale output. Although compatible with the FlexVu Universal Display, the GT3000 is approved as a stand-alone unit and supports local calibration without the FlexVu display.
Description
The Det-Tronics GT3000 line of electrochemical fixed-point toxic-gas detectors provides continuous monitoring of the atmosphere for potentially hazardous toxic gas leaks or oxygen depletion. The GT3000 family currently includes sensors that detect each of the following gases (additional gases added soon): hydrogen sulfide (H2S) hydrogen (H2) oxygen (O2) carbon monoxide (CO) nitrogen dioxide (NO2) ammonia (NH3) chlorine (Cl2) sulfur dioxide (SO2) A complete GT3000 detector consists of a transmitter (GTX) and a sensor module (GTS). The transmitter generates a 4-20 mA output signal with HART that is proportional to the concentration of the target gas and corresponds directly to 0-100% full scale output. Although compatible with the FlexVu Universal Display, the GT3000 is approved as a stand-alone unit and supports local calibration without the FlexVu display.

Suppliers

Company
Product
Description
Supplier Links
Toxic Gas Detector - GT3000 - Det-Tronics
Minneapolis, MN, USA
Toxic Gas Detector
GT3000
Toxic Gas Detector GT3000
The Det-Tronics GT3000 line of electrochemical fixed-point toxic-gas detectors provides continuous monitoring of the atmosphere for potentially hazardous toxic gas leaks or oxygen depletion. The GT3000 family currently includes sensors that detect each of the following gases (additional gases added soon): hydrogen sulfide (H2S) hydrogen (H2) oxygen (O2) carbon monoxide (CO) nitrogen dioxide (NO2) ammonia (NH3) chlorine (Cl2) sulfur dioxide (SO2) A complete GT3000 detector consists of a transmitter (GTX) and a sensor module (GTS). The transmitter generates a 4-20 mA output signal with HART that is proportional to the concentration of the target gas and corresponds directly to 0-100% full scale output. Although compatible with the FlexVu Universal Display, the GT3000 is approved as a stand-alone unit and supports local calibration without the FlexVu display.

The Det-Tronics GT3000 line of electrochemical fixed-point toxic-gas detectors provides continuous monitoring of the atmosphere for potentially hazardous toxic gas leaks or oxygen depletion.

The GT3000 family currently includes sensors that detect each of the following gases (additional gases added soon):

  • hydrogen sulfide (H2S)
  • hydrogen (H2)
  • oxygen (O2)
  • carbon monoxide (CO)
  • nitrogen dioxide (NO2)
  • ammonia (NH3)
  • chlorine (Cl2)
  • sulfur dioxide (SO2)

A complete GT3000 detector consists of a transmitter (GTX) and a sensor module (GTS). The transmitter generates a 4-20 mA output signal with HART that is proportional to the concentration of the target gas and corresponds directly to 0-100% full scale output.

Although compatible with the FlexVu Universal Display, the GT3000 is approved as a stand-alone unit and supports local calibration without the FlexVu display.

Supplier's Site

Technical Specifications

  Det-Tronics
Product Category Gas Transmitters
Product Number GT3000
Product Name Toxic Gas Detector
Measurement Type %Volume; Trace
Gas Types Toxic; NH3; (0-100ppm); CO; (0-500ppm); Cl2; (0-10ppm); H2S; (0-50 ppm; 0-100 ppm); O2; (0-25%); SO2; (0-20 ppm)
Electrical Outputs Current
Display Analog
Features Audible or Visual Alarms; Data Logger; Hazardous Environment; Intrinsically Safe
Unlock Full Specs
to access all available technical data

Similar Products

Flue Gas Oxygen Analyzer - WDG 1200 - LAND
Specs
Measurement Type %Volume
Gas Types Toxic; O2; (From 0 to 1 %, 0 to 25 %)
Electrical Outputs Current; Switch or Relay
View Details
Toxic Gas Transmitter - HLM-2000-TX - Arjay Engineering
Specs
Measurement Type %Volume; Trace
Gas Types Toxic; Combustible; NH3; (0-100ppm); CO; (0-500ppm); Cl2; (0-10ppm); HCl; (0-10ppm); H2S; (0-100ppm); NO; (0-100ppm); NO2; (0-20pm); O2; (0-30%); SO2; (0-50ppm)
Electrical Outputs Current
View Details
Thermal Conductivity Binary Gas Analyzer - XMTCpro - Panametrics
Specs
Measurement Type %Volume
Gas Types CO2; H2; O2; SO2; (He, N2, Ar)
Electrical Outputs Current
View Details
Open Path Gas Detector - Senscient ELDS™ - MSA Safety
Specs
Measurement Type %Volume
Gas Types Toxic; NH3; CO2; HCl; HF; H2S
Electrical Outputs Current
View Details