UL Standards & Engagement Fuseholders - Part 19: Photovoltaic Fuseholders UL 4248-19

Description
1.1 This Part is intended to be read together with the Standard for Fuseholders - Part 1: General Requirements, hereafter referred to as Part 1. The titles of the Clauses in this Part correspond to the similarly titled Clauses in Part 1. The requirements of Part 1 apply unless modified by this Part. For the Part 1 requirements, refer to the Standard for Fuseholders - Part 1: General Requirements, NMX-J-009-4248/1-ANC E / CSA C22.2 No. 4248.1 / UL 4248-1. 1.2 This Part applies to Fuseholders for Photovoltaic (PV) Systems rated to 1500 Vdc. 1.3 This Part applies to PV fuseholders that accommodate PV fuses as described in the Standard for Low-Voltage Fuses - Part 19: Photovoltaic Fuses, NMX-J-009/248/19-ANC E / CSA C22.2 No. 248.19 / UL 248-19 to be employed in Photovoltaic (PV) systems and that are intended to be used in accordance with the Canadian Electrical Code, Part I, CSA C22.1, the National Electrical Code, NFPA 70, and the Mexican Electrical Code, NOM-001. 1.4 Fuseholders that meet another Part also need to comply with those requirements of that Part.
Request a Quote
Description
1.1 This Part is intended to be read together with the Standard for Fuseholders - Part 1: General Requirements, hereafter referred to as Part 1. The titles of the Clauses in this Part correspond to the similarly titled Clauses in Part 1. The requirements of Part 1 apply unless modified by this Part. For the Part 1 requirements, refer to the Standard for Fuseholders - Part 1: General Requirements, NMX-J-009-4248/1-ANC E / CSA C22.2 No. 4248.1 / UL 4248-1. 1.2 This Part applies to Fuseholders for Photovoltaic (PV) Systems rated to 1500 Vdc. 1.3 This Part applies to PV fuseholders that accommodate PV fuses as described in the Standard for Low-Voltage Fuses - Part 19: Photovoltaic Fuses, NMX-J-009/248/19-ANC E / CSA C22.2 No. 248.19 / UL 248-19 to be employed in Photovoltaic (PV) systems and that are intended to be used in accordance with the Canadian Electrical Code, Part I, CSA C22.1, the National Electrical Code, NFPA 70, and the Mexican Electrical Code, NOM-001. 1.4 Fuseholders that meet another Part also need to comply with those requirements of that Part.
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Fuseholders - Part 19: Photovoltaic Fuseholders - UL 4248-19 - UL Standards & Engagement
Evanston, IL, United States
Fuseholders - Part 19: Photovoltaic Fuseholders
UL 4248-19
Fuseholders - Part 19: Photovoltaic Fuseholders UL 4248-19
1.1 This Part is intended to be read together with the Standard for Fuseholders - Part 1: General Requirements, hereafter referred to as Part 1. The titles of the Clauses in this Part correspond to the similarly titled Clauses in Part 1. The requirements of Part 1 apply unless modified by this Part. For the Part 1 requirements, refer to the Standard for Fuseholders - Part 1: General Requirements, NMX-J-009-4248/1-ANC E / CSA C22.2 No. 4248.1 / UL 4248-1. 1.2 This Part applies to Fuseholders for Photovoltaic (PV) Systems rated to 1500 Vdc. 1.3 This Part applies to PV fuseholders that accommodate PV fuses as described in the Standard for Low-Voltage Fuses - Part 19: Photovoltaic Fuses, NMX-J-009/248/19-ANC E / CSA C22.2 No. 248.19 / UL 248-19 to be employed in Photovoltaic (PV) systems and that are intended to be used in accordance with the Canadian Electrical Code, Part I, CSA C22.1, the National Electrical Code, NFPA 70, and the Mexican Electrical Code, NOM-001. 1.4 Fuseholders that meet another Part also need to comply with those requirements of that Part.

1.1 This Part is intended to be read together with the Standard for Fuseholders - Part 1: General Requirements, hereafter referred to as Part 1. The titles of the Clauses in this Part correspond to the similarly titled Clauses in Part 1. The requirements of Part 1 apply unless modified by this Part. For the Part 1 requirements, refer to the Standard for Fuseholders - Part 1: General Requirements, NMX-J-009-4248/1-ANCE / CSA C22.2 No. 4248.1 / UL 4248-1.

1.2 This Part applies to Fuseholders for Photovoltaic (PV) Systems rated to 1500 Vdc.

1.3 This Part applies to PV fuseholders that accommodate PV fuses as described in the Standard for Low-Voltage Fuses - Part 19: Photovoltaic Fuses, NMX-J-009/248/19-ANCE / CSA C22.2 No. 248.19 / UL 248-19 to be employed in Photovoltaic (PV) systems and that are intended to be used in accordance with the Canadian Electrical Code, Part I, CSA C22.1, the National Electrical Code, NFPA 70, and the Mexican Electrical Code, NOM-001.

1.4 Fuseholders that meet another Part also need to comply with those requirements of that Part.

Supplier's Site