Take advantage of an existing in-house water system for heat removal. Thermo Scientific™ System Water-to-Water Heat Exchangers use less energy and cost less to operate than traditional compressor-based chillers. They provide a clean, stable, controlled, closed-loop water cooling system that rejects the process heat into an existing in-house facility water supply. This eliminates the problems associated with the direct use of in-house water such as insufficient or fluctuating flow, changing pressure, poor water quality and temperature instability.
Cooling capacities up to 100kW
Simple, reliable design for years of worry-free operation
Compact footprint optimizes valuable floor space
Heat load sensing valve conserves facility water usage
Panel-mounted gauges monitor recirculating temperatures and fluid pressure (SYS-I and SYS-II)
Flow control valve allows precise setting of recirculating rate (SYS-III and SYS-IV)
High-temperature and low-liquid-level safety feature with status relay povide protection to temperature-sensitiv
e applications
Recommended for:
Laboratory
Laser
Industrial
Semiconductor
Medical
Note:
Cooling capacity is based on a 10°C temperature differential between the cooling water supply and the cooling fluid flowing from the System to the instrument being cooled.
Take advantage of an existing in-house water system for heat removal. Thermo Scientific™ System Water-to-Water Heat Exchangers use less energy and cost less to operate than traditional compressor-based chillers. They provide a clean, stable, controlled, closed-loop water cooling system that rejects the process heat into an existing in-house facility water supply. This eliminates the problems associated with the direct use of in-house water such as insufficient or fluctuating flow, changing pressure, poor water quality and temperature instability.
- Cooling capacities up to 100kW
- Simple, reliable design for years of worry-free operation
- Compact footprint optimizes valuable floor space
- Heat load sensing valve conserves facility water usage
- Panel-mounted gauges monitor recirculating temperatures and fluid pressure (SYS-I and SYS-II)
- Flow control valve allows precise setting of recirculating rate (SYS-III and SYS-IV)
- High-temperature and low-liquid-level safety feature with status relay povide protection to temperature-sensitive applications
Recommended for:
- Laboratory
- Laser
- Industrial
- Semiconductor
- Medical
Note:
Cooling capacity is based on a 10°C temperature differential between the cooling water supply and the cooling fluid flowing from the System to the instrument being cooled.