Sealevel Systems, Inc. SeaRAQ 8 Isolated Form A Relay Outputs 8521

Description
SeaRAQ™ I/O expansion modules provide unprecedented expansion capabilities for Sealevel Relio R3 and Relio R4 industrial computers. The SeaRAQ 8521 expansion board adds 8 isolated relay outputs rated for 5-250 VAC and 5-30 VDC. The Form A relays each have a discrete common and support a maximum 4A current load. The SPST relays are normally open and close when energized. To protect the host computer from harmful voltage spikes commonly found in industrial environments, the 8521 provides 1500 VAC isolation. For easy, reliable field wiring, the board uses removable, high-retention terminal block connectors. Sealevel’s SeaMAX software drivers and utilities make installation and operation easy using Microsoft Windows and Linux operating systems. Communicate using industry standard Modbus RTU protocol or use the Sealevel SeaMAX API software libraries from your application program. Get a jumpstart on your digital I/O development with The Digital I/O Handbook that will provide helpful information that you will use again and again. Check out Chapter 1 for an overview of logic principles.
Description
SeaRAQ™ I/O expansion modules provide unprecedented expansion capabilities for Sealevel Relio R3 and Relio R4 industrial computers. The SeaRAQ 8521 expansion board adds 8 isolated relay outputs rated for 5-250 VAC and 5-30 VDC. The Form A relays each have a discrete common and support a maximum 4A current load. The SPST relays are normally open and close when energized. To protect the host computer from harmful voltage spikes commonly found in industrial environments, the 8521 provides 1500 VAC isolation. For easy, reliable field wiring, the board uses removable, high-retention terminal block connectors. Sealevel’s SeaMAX software drivers and utilities make installation and operation easy using Microsoft Windows and Linux operating systems. Communicate using industry standard Modbus RTU protocol or use the Sealevel SeaMAX API software libraries from your application program. Get a jumpstart on your digital I/O development with The Digital I/O Handbook that will provide helpful information that you will use again and again. Check out Chapter 1 for an overview of logic principles.

Suppliers

Company
Product
Description
Supplier Links
SeaRAQ 8 Isolated Form A Relay Outputs - 8521 - Sealevel Systems, Inc.
Liberty, SC, USA
SeaRAQ 8 Isolated Form A Relay Outputs
8521
SeaRAQ 8 Isolated Form A Relay Outputs 8521
SeaRAQ™ I/O expansion modules provide unprecedented expansion capabilities for Sealevel Relio R3 and Relio R4 industrial computers. The SeaRAQ 8521 expansion board adds 8 isolated relay outputs rated for 5-250 VAC and 5-30 VDC. The Form A relays each have a discrete common and support a maximum 4A current load. The SPST relays are normally open and close when energized. To protect the host computer from harmful voltage spikes commonly found in industrial environments, the 8521 provides 1500 VAC isolation. For easy, reliable field wiring, the board uses removable, high-retention terminal block connectors. Sealevel’s SeaMAX software drivers and utilities make installation and operation easy using Microsoft Windows and Linux operating systems. Communicate using industry standard Modbus RTU protocol or use the Sealevel SeaMAX API software libraries from your application program. Get a jumpstart on your digital I/O development with The Digital I/O Handbook that will provide helpful information that you will use again and again. Check out Chapter 1 for an overview of logic principles.

SeaRAQ™ I/O expansion modules provide unprecedented expansion capabilities for Sealevel Relio R3 and Relio R4 industrial computers. The SeaRAQ 8521 expansion board adds 8 isolated relay outputs rated for 5-250 VAC and 5-30 VDC. The Form A relays each have a discrete common and support a maximum 4A current load. The SPST relays are normally open and close when energized.

To protect the host computer from harmful voltage spikes commonly found in industrial environments, the 8521 provides 1500 VAC isolation. For easy, reliable field wiring, the board uses removable, high-retention terminal block connectors.

Sealevel’s SeaMAX software drivers and utilities make installation and operation easy using Microsoft Windows and Linux operating systems. Communicate using industry standard Modbus RTU protocol or use the Sealevel SeaMAX API software libraries from your application program.

Get a jumpstart on your digital I/O development with The Digital I/O Handbook that will provide helpful information that you will use again and again. Check out Chapter 1 for an overview of logic principles.

Supplier's Site

Technical Specifications

  Sealevel Systems, Inc.
Product Category Data Acquisition
Product Number 8521
Product Name SeaRAQ 8 Isolated Form A Relay Outputs
Data Acquisition Input/Output Module
Unlock Full Specs
to access all available technical data

Similar Products

Smart Distance Sensor - DSS 015 - STEGO
Specs
Data Acquisition Input/Output Module
View Details
Input Module - 240 Series - Lake Shore Cryotronics, Inc.
Lake Shore Cryotronics, Inc.
Specs
Data Acquisition Input Module
Form Factor DIN Rail
Host Connection USB
View Details
Digital Hydraulic Tester - Serviceman Plus - HydraCheck Inc.
Specs
Data Acquisition DAQ Instrument
Form Factor Stand-alone
User Interface Front Panel
View Details