Restek Rtx®-Volatile Amine Columns

Description
Unique selectivity for baseline resolution of all volatile amines. Excellent inertness assures accuracy and sensitivity for volatile amines, including free ammonia. Highly robust phase withstands repeated water injections, resulting in longer column lifetime. High temperature stability (290 °C) ensures elution of amines up to C16 and allows contaminants to be removed by “baking out” the column. Similar Phase(s): Direct replacement for CP-Volamine, thick-film CP-Sil 8 for amines, and other amine-deactivated columns coated with low polarity polysiloxane phases.
Description
Unique selectivity for baseline resolution of all volatile amines. Excellent inertness assures accuracy and sensitivity for volatile amines, including free ammonia. Highly robust phase withstands repeated water injections, resulting in longer column lifetime. High temperature stability (290 °C) ensures elution of amines up to C16 and allows contaminants to be removed by “baking out” the column. Similar Phase(s): Direct replacement for CP-Volamine, thick-film CP-Sil 8 for amines, and other amine-deactivated columns coated with low polarity polysiloxane phases.

Suppliers

Company
Product
Description
Supplier Links
Rtx®-Volatile Amine Columns -  - Restek
Bellefonte, PA, USA
Rtx®-Volatile Amine Columns
Rtx®-Volatile Amine Columns
Unique selectivity for baseline resolution of all volatile amines. Excellent inertness assures accuracy and sensitivity for volatile amines, including free ammonia. Highly robust phase withstands repeated water injections, resulting in longer column lifetime. High temperature stability (290 °C) ensures elution of amines up to C16 and allows contaminants to be removed by “baking out” the column. Similar Phase(s): Direct replacement for CP-Volamine, thick-film CP-Sil 8 for amines, and other amine-deactivated columns coated with low polarity polysiloxane phases.
  • Unique selectivity for baseline resolution of all volatile amines.
  • Excellent inertness assures accuracy and sensitivity for volatile amines, including free ammonia.
  • Highly robust phase withstands repeated water injections, resulting in longer column lifetime.
  • High temperature stability (290 °C) ensures elution of amines up to C16 and allows contaminants to be removed by “baking out” the column.

Similar Phase(s):

Direct replacement for CP-Volamine, thick-film CP-Sil 8 for amines, and other amine-deactivated columns coated with low polarity polysiloxane phases.

Supplier's Site

Technical Specifications

  Restek
Product Category GC Columns
Product Name Rtx®-Volatile Amine Columns
Column Type Capillary
Unlock Full Specs
to access all available technical data

Similar Products

Abel Industries Canada Ltd.
Specs
Column Length 60 m (197 ft)
Inner Diameter (ID) 320 µm (12.6 mils)
Film Thickness 0.5000 µm (0.0197 mils)
View Details
CarboBlack Packing Materials -  - Restek
Specs
Column Type Packed
Operating Temperature ? to 932 F (? to 500 C)
View Details
Abel Industries Canada Ltd.
Specs
Column Length 12 m (39.37 ft)
Inner Diameter (ID) 200 µm (7.87 mils)
Film Thickness 0.3300 µm (0.0130 mils)
View Details
Rtx®-225 Columns -  - Restek
Specs
Column Type Capillary
Construction Material Silicate Glass; Other; Fused Silica
Column Length 15 to 60 m (49.21 to 197 ft)
View Details