Restek Rt®-608Pkd Columns

Description
Optimized for pesticide analysis by US EPA Method 608. Pesticide analysis remains the largest environmental application for packed columns. Currently, mixed phase packed columns do not offer complete resolution of chlorinated pesticides, and require long analysis times (nearly 40 minutes). Restek has developed a special packing material that exceeds EPA Method 608 resolution requirements while delivering a faster analysis time than any other pesticide phase packed column available. Inert SilcoSmooth® tubing and highly inert Silcoport® support make it possible to analyze chlorinated pesticides at levels below 50pg—performance that is nearly impossible with older packed column technology. The computer-modeled phase resolves all 18 peaks in US EPA Method 608 in less than 12 minutes—one-third the time previously required! Compare the performances of conventional 1.5% SP-2250/1.95% SP-2401 pesticide packing and innovative Rt®-608Pkd packing, and you’ll stop wasting time with old technology.
Description
Optimized for pesticide analysis by US EPA Method 608. Pesticide analysis remains the largest environmental application for packed columns. Currently, mixed phase packed columns do not offer complete resolution of chlorinated pesticides, and require long analysis times (nearly 40 minutes). Restek has developed a special packing material that exceeds EPA Method 608 resolution requirements while delivering a faster analysis time than any other pesticide phase packed column available. Inert SilcoSmooth® tubing and highly inert Silcoport® support make it possible to analyze chlorinated pesticides at levels below 50pg—performance that is nearly impossible with older packed column technology. The computer-modeled phase resolves all 18 peaks in US EPA Method 608 in less than 12 minutes—one-third the time previously required! Compare the performances of conventional 1.5% SP-2250/1.95% SP-2401 pesticide packing and innovative Rt®-608Pkd packing, and you’ll stop wasting time with old technology.

Suppliers

Company
Product
Description
Supplier Links
Rt®-608Pkd Columns -  - Restek
Bellefonte, PA, USA
Rt®-608Pkd Columns
Rt®-608Pkd Columns
Optimized for pesticide analysis by US EPA Method 608. Pesticide analysis remains the largest environmental application for packed columns. Currently, mixed phase packed columns do not offer complete resolution of chlorinated pesticides, and require long analysis times (nearly 40 minutes). Restek has developed a special packing material that exceeds EPA Method 608 resolution requirements while delivering a faster analysis time than any other pesticide phase packed column available. Inert SilcoSmooth® tubing and highly inert Silcoport® support make it possible to analyze chlorinated pesticides at levels below 50pg—performance that is nearly impossible with older packed column technology. The computer-modeled phase resolves all 18 peaks in US EPA Method 608 in less than 12 minutes—one-third the time previously required! Compare the performances of conventional 1.5% SP-2250/1.95% SP-2401 pesticide packing and innovative Rt®-608Pkd packing, and you’ll stop wasting time with old technology.

Optimized for pesticide analysis by US EPA Method 608.

Pesticide analysis remains the largest environmental application for packed columns. Currently, mixed phase packed columns do not offer complete resolution of chlorinated pesticides, and require long analysis times (nearly 40 minutes).
Restek has developed a special packing material that exceeds EPA Method 608 resolution requirements while delivering a faster analysis time than any other pesticide phase packed column available. Inert SilcoSmooth® tubing and highly inert Silcoport® support make it possible to analyze chlorinated pesticides at levels below 50pg—performance that is nearly impossible with older packed column technology. The computer-modeled phase resolves all 18 peaks in US EPA Method 608 in less than 12 minutes—one-third the time previously required! Compare the performances of conventional 1.5% SP-2250/1.95% SP-2401 pesticide packing and innovative Rt®-608Pkd packing, and you’ll stop wasting time with old technology.

Supplier's Site

Technical Specifications

  Restek
Product Category GC Columns
Product Name Rt®-608Pkd Columns
Column Type Packed
Unlock Full Specs
to access all available technical data

Similar Products

Abel Industries Canada Ltd.
Specs
Column Length 30 m (98.43 ft)
Inner Diameter (ID) 320 µm (12.6 mils)
Film Thickness 25 µm (0.9843 mils)
View Details
Innovative Integra-Guard®Columns -  - Restek
Specs
Column Type Capillary
Construction Material Silicate Glass; Other; Fused Silica
Column Length 15 to 60 m (49.21 to 197 ft)
View Details
Abel Industries Canada Ltd.
Specs
Column Length 15 m (49.21 ft)
Inner Diameter (ID) 320 µm (12.6 mils)
Film Thickness 0.5000 µm (0.0197 mils)
View Details
Rtx®-Dioxin2 Columns -  - Restek
Specs
Column Type Capillary
Construction Material Silicate Glass; Other; Fused Silica
Column Length 40 to 60 m (131 to 197 ft)
View Details