Stable up to 450 °C—lowest bleed for longest column lifetime. Reliably meet all ASTM D6352, D7169, and D7500 specifications. 100% dimethyl polysiloxane phase allows easy comparisons to historical data. Accurate boiling point determination for medium and heavy fractions using GC simulated distillation requires columns and phase polymers that are robust enough to withstand high temperatures without significant degradation. Metal columns are a better alternative than fused silica, and the MXT®-1HT SimDist columns are the lowest bleed, highest efficiency columns available, outperforming other metal columns for critical method parameters.
Description
Stable up to 450 °C—lowest bleed for longest column lifetime. Reliably meet all ASTM D6352, D7169, and D7500 specifications. 100% dimethyl polysiloxane phase allows easy comparisons to historical data. Accurate boiling point determination for medium and heavy fractions using GC simulated distillation requires columns and phase polymers that are robust enough to withstand high temperatures without significant degradation. Metal columns are a better alternative than fused silica, and the MXT®-1HT SimDist columns are the lowest bleed, highest efficiency columns available, outperforming other metal columns for critical method parameters.

Suppliers

Company
Product
Description
Supplier Links
MXT®-1HT SimDist Column -  - Restek
Bellefonte, PA, USA
MXT®-1HT SimDist Column
MXT®-1HT SimDist Column
Stable up to 450 °C—lowest bleed for longest column lifetime. Reliably meet all ASTM D6352, D7169, and D7500 specifications. 100% dimethyl polysiloxane phase allows easy comparisons to historical data. Accurate boiling point determination for medium and heavy fractions using GC simulated distillation requires columns and phase polymers that are robust enough to withstand high temperatures without significant degradation. Metal columns are a better alternative than fused silica, and the MXT®-1HT SimDist columns are the lowest bleed, highest efficiency columns available, outperforming other metal columns for critical method parameters.
  • Stable up to 450 °C—lowest bleed for longest column lifetime.
  • Reliably meet all ASTM D6352, D7169, and D7500 specifications.
  • 100% dimethyl polysiloxane phase allows easy comparisons to historical data.

Accurate boiling point determination for medium and heavy fractions using GC simulated distillation requires columns and phase polymers that are robust enough to withstand high temperatures without significant degradation. Metal columns are a better alternative than fused silica, and the MXT®-1HT SimDist columns are the lowest bleed, highest efficiency columns available, outperforming other metal columns for critical method parameters.

Supplier's Site

Technical Specifications

  Restek
Product Category GC Columns
Product Name MXT®-1HT SimDist Column
Column Type Capillary
Construction Material Stainless Steel
Column Length 5 to 10 m (16.4 to 32.81 ft)
Unlock Full Specs
to access all available technical data

Similar Products

MXT®-50 Columns -  - Restek
Specs
Column Type Capillary
Construction Material Stainless Steel
Column Length 15 to 60 m (49.21 to 197 ft)
View Details
Abel Industries Canada Ltd.
Specs
Column Length 10 m (32.81 ft)
Inner Diameter (ID) 180 µm (7.09 mils)
Film Thickness 0.4000 µm (0.0157 mils)
View Details
Stx®-CLPesticides Column Kits -  - Restek
Specs
Column Type Capillary
Construction Material Silicate Glass; Other; Fused Silica