Pfeiffer Vacuum, Inc. Residual gas analysis systems OmniGrade

Description
Flexible: Modular design, individual configuration for specific process requirements Proven: Testing according to Generic Standards GSA 07 1221 and GSA 07 2221 High performance: Low detection limits, fully automated measuring process
Request a Quote
Description
Flexible: Modular design, individual configuration for specific process requirements Proven: Testing according to Generic Standards GSA 07 1221 and GSA 07 2221 High performance: Low detection limits, fully automated measuring process
Request a Quote
Datasheet
Datasheet Summary
Powered by GS/AI

OmniGrade is a residual gas analysis system with a modular design for configurable process requirements, featuring a 3-chamber system accommodating samples up to 150 x 150 x 150 mm³ or a 2-chamber system for samples up to 700 x 700 x 700 mm³. It achieves an ultimate pressure below 5 × 10⁻¹⁰ hPa using HiPace 300 M and dry forevacuum pumps, with partial pressure analysis via PrismaPro or HiQuad Neo quadrupole mass spectrometers. The system includes heating up to 180 °C with jackets, cooling via a silicone-free thermofluid system, and calibration using an UHV all-metal leak valve and calibrated N₂ leak. It is operated through a PLC with a 19" full HD touch display and measures 1.1 x 1.9 x 2.3 m in dimensions. Testing conforms to Generic Standards GSA 07 1221 and GSA 07 2221.

Datasheet Summary
Powered by GS/AI

OmniGrade is a residual gas analysis system with a modular design for configurable process requirements, featuring a 3-chamber system accommodating samples up to 150 x 150 x 150 mm³ or a 2-chamber system for samples up to 700 x 700 x 700 mm³. It achieves an ultimate pressure below 5 × 10⁻¹⁰ hPa using HiPace 300 M and dry forevacuum pumps, with partial pressure analysis via PrismaPro or HiQuad Neo quadrupole mass spectrometers. The system includes heating up to 180 °C with jackets, cooling via a silicone-free thermofluid system, and calibration using an UHV all-metal leak valve and calibrated N₂ leak. It is operated through a PLC with a 19" full HD touch display and measures 1.1 x 1.9 x 2.3 m in dimensions. Testing conforms to Generic Standards GSA 07 1221 and GSA 07 2221.

Suppliers

Company
Product
Description
Supplier Links
Residual gas analysis systems - OmniGrade - Pfeiffer Vacuum, Inc.
Nashua, NH, United States
Residual gas analysis systems
OmniGrade
Residual gas analysis systems OmniGrade
Flexible: Modular design, individual configuration for specific process requirements Proven: Testing according to Generic Standards GSA 07 1221 and GSA 07 2221 High performance: Low detection limits, fully automated measuring process

Flexible: Modular design, individual configuration for specific process requirements Proven: Testing according to Generic Standards GSA 07 1221 and GSA 07 2221 High performance: Low detection limits, fully automated measuring process

Supplier's Site Datasheet

Technical Specifications

  Pfeiffer Vacuum, Inc.
Product Category Residual Gas Analyzers
Product Number OmniGrade
Product Name Residual gas analysis systems
Display video
Unlock Full Specs
to access all available technical data

Similar Products

Residual gas analysis systems - HiCube Neo RGA (QMG 250 M3) - Pfeiffer Vacuum, Inc.
Specs
Detector Type Faraday Cup; Other; C-SEM, Faraday
Mass Range 1 to 300 (amu)
Sensitivity 3 · 10⁻⁴ A/hPa (mbar)
View Details
Residual gas analysis systems - HiCube Neo RGA (QMG 250 F2) - Pfeiffer Vacuum, Inc.
Specs
Detector Type Faraday Cup; Other; Faraday
Mass Range 1 to 200 (amu)
Sensitivity 4 · 10⁻⁴ A/hPa (mbar)
View Details
Residual gas analysis systems - HiCube Neo RGA (QMG 250 M2) - Pfeiffer Vacuum, Inc.
Specs
Detector Type Faraday Cup; Other; C-SEM, Faraday
Mass Range 1 to 200 (amu)
Sensitivity 4 · 10⁻⁴ A/hPa (mbar)
View Details
Residual gas analysis systems - HiCube Neo RGA (QMG 250 F3) - Pfeiffer Vacuum, Inc.
Specs
Detector Type Faraday Cup; Other; Faraday
Mass Range 1 to 300 (amu)
Sensitivity 3 · 10⁻⁴ A/hPa (mbar)
View Details