UL and C-UL listed
Conforms to EN60204-1, EN954-1, ISOTR 12100
Power requirements-the SR203M/A will accept 24 VAC/DC or 115 VAC
Inputs-the SR203M/A will accept single or dual N/C inputs or dual PNP inputs from a light curtain
Outputs-the SR203M/A has 3 N/O outputs to route power to the coils of power contactors, plus 1 N/C auxiliary output for signaling purposes
External Device Monitoring (EDM) is provided with a N/C loop between S12 and S34 on the SR203M/A
Monitored manual or automatic/ manual reset modes are available on the SR203M/A
The SR203M/A have removable terminal blocks
UL and C-UL listed
Conforms to EN60204-1, EN954-1, ISOTR 12100
- Power requirements-the SR203M/A will accept 24 VAC/DC or 115 VAC
- Inputs-the SR203M/A will accept single or dual N/C inputs or dual PNP inputs from a light curtain
- Outputs-the SR203M/A has 3 N/O outputs to route power to the coils of power contactors, plus 1 N/C auxiliary output for signaling purposes
- External Device Monitoring (EDM) is provided with a N/C loop between S12 and S34 on the SR203M/A
- Monitored manual or automatic/ manual reset modes are available on the SR203M/A
- The SR203M/A have removable terminal blocks