Maury Microwave VNA Calibration Standard 7942C25

Description
Maury mismatch airlines have been designed as verification standards to be used in VNA calibration validation. Each mismatch airline is provided with factory S-parameters data that can be compared with user-measured S-parameters for VNA calibration validation. Measurement uncertainty is also provided, and uncertainty boundaries can be used for definitive calibration validation when used in conjunction with MT940B Insight Real-Time Uncertainty Add-On.
Request a Quote
Description
Maury mismatch airlines have been designed as verification standards to be used in VNA calibration validation. Each mismatch airline is provided with factory S-parameters data that can be compared with user-measured S-parameters for VNA calibration validation. Measurement uncertainty is also provided, and uncertainty boundaries can be used for definitive calibration validation when used in conjunction with MT940B Insight Real-Time Uncertainty Add-On.
Request a Quote
Datasheet
Datasheet Summary
Powered by GS/AI

The 7942C25 is a VNA calibration verification standard with a 2.4mm connector, designed for use in calibration validation. It operates from DC to 50.0 GHz, has an electrical length of 4.110 cm, an impedance of 25 Ω, and an electrical length accuracy of ±0.02 cm. It is provided with factory-measured S-parameters and associated measurement uncertainty data for comparison with user measurements.

Datasheet Summary
Powered by GS/AI

The 7942C25 is a VNA calibration verification standard with a 2.4mm connector, designed for use in calibration validation. It operates from DC to 50.0 GHz, has an electrical length of 4.110 cm, an impedance of 25 Ω, and an electrical length accuracy of ±0.02 cm. It is provided with factory-measured S-parameters and associated measurement uncertainty data for comparison with user measurements.

Suppliers

Company
Product
Description
Supplier Links
VNA Calibration Standard - 7942C25 - Maury Microwave
Ontario, CA, United States
VNA Calibration Standard
7942C25
VNA Calibration Standard 7942C25
Maury mismatch airlines have been designed as verification standards to be used in VNA calibration validation. Each mismatch airline is provided with factory S-parameters data that can be compared with user-measured S-parameters for VNA calibration validation. Measurement uncertainty is also provided, and uncertainty boundaries can be used for definitive calibration validation when used in conjunction with MT940B Insight Real-Time Uncertainty Add-On.

Maury mismatch airlines have been designed as verification standards to be used in VNA calibration validation. Each mismatch airline is provided with factory S-parameters data that can be compared with user-measured S-parameters for VNA calibration validation. Measurement uncertainty is also provided, and uncertainty boundaries can be used for definitive calibration validation when used in conjunction with MT940B Insight Real-Time Uncertainty Add-On.

Supplier's Site Datasheet

Technical Specifications

  Maury Microwave
Product Category Calibration Instruments
Product Number 7942C25
Product Name VNA Calibration Standard
Calibration Signal Signal / Waveform Generator Output
Unlock Full Specs
to access all available technical data

Similar Products

VNA Calibration Standard - 7946A2 - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 2.60E9 to 5.00E10 Hz
View Details
VNA Calibration Standard - 360B - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 2.60E9 to 5.00E10 Hz
View Details
VNA Calibration Standard - 8031B6 - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 2.60E9 to 5.00E10 Hz
Electrical Properties Resistance/ Impedance
View Details
Automated Tuner - XT981HL13 - Maury Microwave
Specs
Calibration Signal Signal / Waveform Generator Output
Frequency Range 8.00E9 Hz
Electrical Properties Resistance/ Impedance
View Details