HVACQuick.com Tjernlund PS1503 Positive Air Flow Pressure Switch PS1503

Description
Tjernlund Duct Airstat Pressure Fan Switch. 15 amp switching capability. The Tjernlund Duct Airstat senses positive pressure in a forced air heating and/or cooling system. The single pole, single throw, snap-acting switch is activated by a diaphragm with a factory installed sampling tube inserted directly into the duct or plenum. The Duct Airstat can be used to initiate such auxiliary devices as: Duct Boosters, Electronic Air Cleaners, Electrical Duct Heaters, and Humidifiers. The electrical contacts of the switch are closed upon sensing positive air pressure generated by the blower.
Description
Tjernlund Duct Airstat Pressure Fan Switch. 15 amp switching capability. The Tjernlund Duct Airstat senses positive pressure in a forced air heating and/or cooling system. The single pole, single throw, snap-acting switch is activated by a diaphragm with a factory installed sampling tube inserted directly into the duct or plenum. The Duct Airstat can be used to initiate such auxiliary devices as: Duct Boosters, Electronic Air Cleaners, Electrical Duct Heaters, and Humidifiers. The electrical contacts of the switch are closed upon sensing positive air pressure generated by the blower.

Suppliers

Company
Product
Description
Supplier Links
Tjernlund PS1503 Positive Air Flow Pressure Switch - PS1503 - HVACQuick.com
Medford, OR, USA
Tjernlund PS1503 Positive Air Flow Pressure Switch
PS1503
Tjernlund PS1503 Positive Air Flow Pressure Switch PS1503
Tjernlund Duct Airstat Pressure Fan Switch. 15 amp switching capability. The Tjernlund Duct Airstat senses positive pressure in a forced air heating and/or cooling system. The single pole, single throw, snap-acting switch is activated by a diaphragm with a factory installed sampling tube inserted directly into the duct or plenum. The Duct Airstat can be used to initiate such auxiliary devices as: Duct Boosters, Electronic Air Cleaners, Electrical Duct Heaters, and Humidifiers. The electrical contacts of the switch are closed upon sensing positive air pressure generated by the blower.

Tjernlund Duct Airstat Pressure Fan Switch. 15 amp switching capability.

The Tjernlund Duct Airstat senses positive pressure in a forced air heating and/or cooling system. The single pole, single throw, snap-acting switch is activated by a diaphragm with a factory installed sampling tube inserted directly into the duct or plenum.

The Duct Airstat can be used to initiate such auxiliary devices as: Duct Boosters, Electronic Air Cleaners, Electrical Duct Heaters, and Humidifiers. The electrical contacts of the switch are closed upon sensing positive air pressure generated by the blower.

Supplier's Site

Technical Specifications

  HVACQuick.com
Product Category Pressure Switches
Product Number PS1503
Product Name Tjernlund PS1503 Positive Air Flow Pressure Switch
Pressure Measurement Absolute (optional feature)
Unlock Full Specs
to access all available technical data

Similar Products

PS80 50psi Pressure Switch, NO; 18" PS80-K2-F0316 -  - Sensata Technologies
Specs
Pressure Measurement Gauge
Working Pressure Range 0.0 to 750 psi (0.0 to 528 m H2O)
Operating Temperature -65 to 275 F (-54 to 135 C)
View Details
Pressure Sensors, Transducers - Industrial - 1882-6074056-ND - DigiKey
Specs
Pressure Measurement Gauge
Working Pressure Range 5802 psi (4083 m H2O)
Accuracy 0.5000 ±% FS
View Details
160P NEMA 4 & 13 Differential Pressure Switch -  - Neo-Dyn
Specs
Pressure Measurement Differential
Operating Temperature -40 to 250 F (-40 to 121 C)
View Details
Vacuum Switches - 1215596 - RS Components, Ltd.
RS Components, Ltd.
Specs
Pressure Measurement Vacuum; Relative Pressure
Working Pressure Range 14.5 psi (10.21 m H2O)
Vacuum Range 750 torr (0.3825 in Hg vac)
View Details