Excelitas Noblelight America LLC Light Solution for NOx Measurement

Request a Quote Datasheet

Suppliers

Company
Product
Description
Supplier Links
Light Solution for NOx Measurement -  - Excelitas Noblelight America LLC
Gaithersburg, MD, United States
Light Solution for NOx Measurement
Light Solution for NOx Measurement
Common methods for measuring NOx include sensor technologies based on chemiluminescence and electrochemical techniques. The electrochemical technique can not measure NO and NO2 at one time. Chemiluminescence requires conversion of NO2 to NO for measurement of the NO2 content based on an assumed NO: NO2 ratio. In addition, measurements can be affected by the content of H2O and CO2. Direct measurement of both NO and NO2 is the more precise way to measure Total NOx for Continuous Emissions Monitoring and measurement in the UV-region avoids the influence of H2O and CO2. System development based on UV Resonance Absorption Spectroscopy (UV-RAS) has been difficult in the past due to challenges in tuning the UV-lamp operation with its environment. Pre-tuned NOx UV-Light Source from Heraeus Now the Heraeus NOx Module overcomes this problem by offering a pre-tuned UV-light source in a stable environment, for easy integration as a Plug & Play Module into OEM UV-RAS systems. The Heraeus NOx Module has an integrated Electrodeless Discharge Lamp (EDL) and comes with the corresponding power supply combined in a compact box. The NOx-Module is designed for direct illumination of the measurement cell, so there is no additional optical connection needed. Your advantages High quality measurement - no crossover of H2O, CO and CO2 and good sensitivity because of NOx-specific emission lines Reduced design-in costs - complete Plug & Play module for a simple integration in your system Pre-tuned settings - Optimized settings for a long lifetime and performance Less operating costs - No consumables per measurement and easy replacement of the module Application areas Sources of NOx are predominantly man-made: burning fossil fuels for energy generation, such as coal-,oil- and gas-fired power stations, refuse incineration, some chemical processes and vehicle fuels, like modern diesel cars, used for land, water and air transportation. NOx measurement is used for: Environmental monitoring Smoke stack monitoring Emission control testing Marine exhaust monitoring Air quality monitoring

Common methods for measuring NOx include sensor technologies based on chemiluminescence and electrochemical techniques. The electrochemical technique can not measure NO and NO2 at one time. Chemiluminescence requires conversion of NO2 to NO for measurement of the NO2 content based on an assumed NO: NO2 ratio. In addition, measurements can be affected by the content of H2O and CO2. Direct measurement of both NO and NO2 is the more precise way to measure Total NOx for Continuous Emissions Monitoring and measurement in the UV-region avoids the influence of H2O and CO2. System development based on UV Resonance Absorption Spectroscopy (UV-RAS) has been difficult in the past due to challenges in tuning the UV-lamp operation with its environment. Pre-tuned NOx UV-Light Source from Heraeus Now the Heraeus NOx Module overcomes this problem by offering a pre-tuned UV-light source in a stable environment, for easy integration as a Plug & Play Module into OEM UV-RAS systems. The Heraeus NOx Module has an integrated Electrodeless Discharge Lamp (EDL) and comes with the corresponding power supply combined in a compact box. The NOx-Module is designed for direct illumination of the measurement cell, so there is no additional optical connection needed. Your advantages High quality measurement - no crossover of H2O, CO and CO2 and good sensitivity because of NOx-specific emission lines Reduced design-in costs - complete Plug & Play module for a simple integration in your system Pre-tuned settings - Optimized settings for a long lifetime and performance Less operating costs - No consumables per measurement and easy replacement of the module Application areas Sources of NOx are predominantly man-made: burning fossil fuels for energy generation, such as coal-,oil- and gas-fired power stations, refuse incineration, some chemical processes and vehicle fuels, like modern diesel cars, used for land, water and air transportation. NOx measurement is used for: Environmental monitoring Smoke stack monitoring Emission control testing Marine exhaust monitoring Air quality monitoring

Supplier's Site Datasheet

Technical Specifications

  Excelitas Noblelight America LLC
Product Category Spectral Lamps
Product Name Light Solution for NOx Measurement
Rated Average Life 8000 hours
Unlock Full Specs
to access all available technical data

Similar Products

Heraeus Xenon Flash Lamp -  - Excelitas Noblelight America LLC
Excelitas Noblelight America LLC
Specs
High Intensity Discharge Lamps Xenon
Flash Lamp Flash Lamp
Lamp Power 16 watts
View Details
Low Pressure UV Mercury Vapor Lamps - HG-2 - Excelitas Noblelight America LLC
Excelitas Noblelight America LLC
Specs
Spectral Lamp Mercury
Lamp Power 2.7 watts
Wavelength Range 254 to 435 µm (2.54E6 to 4.35E6 Å)
View Details
Low Pressure UV Mercury Vapor Lamps - HG-2 - Excelitas Noblelight America LLC
Excelitas Noblelight America LLC
Specs
Spectral Lamp Mercury
Lamp Power 2.7 watts
Wavelength Range 254 to 435 µm (2.54E6 to 4.35E6 Å)
View Details
Heraeus Xenon Flash Lamp -  - Excelitas Noblelight America LLC
Excelitas Noblelight America LLC
Specs
High Intensity Discharge Lamps Xenon
Flash Lamp Flash Lamp
Lamp Power 16 watts
View Details