Hammond Manufacturing Company Inc. Transformers - Classic Transformers 260A6

Description
Features Universal primary with taps for 100, 120, 220 or 240 VAC, 50/60 Hz. (Except the 260A6 which is 117V, 50/60 Hz only) Designed for preamps, low power amps, general replacement, test equipment, etc. Economical, open frame, chassis mount - two hole (.187 dia. = G) channel bracket (figure #1) or four hole mounting (figure #2). Units include a Faraday shield between the primary and secondary windings. Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries. Minimum 5" long leads. For more selection check out our 300 Series of universal plate & filament transformers. NOTES These units are designed to run with BOTH primary windings energized for maximum efficiency (see wiring table below). The Faraday shield lead - the gray wire - marked SH (shield) above, should remain grounded to the mounting bracket & in turn to the chassis.
Request a Quote Datasheet
Description
Features Universal primary with taps for 100, 120, 220 or 240 VAC, 50/60 Hz. (Except the 260A6 which is 117V, 50/60 Hz only) Designed for preamps, low power amps, general replacement, test equipment, etc. Economical, open frame, chassis mount - two hole (.187 dia. = G) channel bracket (figure #1) or four hole mounting (figure #2). Units include a Faraday shield between the primary and secondary windings. Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries. Minimum 5" long leads. For more selection check out our 300 Series of universal plate & filament transformers. NOTES These units are designed to run with BOTH primary windings energized for maximum efficiency (see wiring table below). The Faraday shield lead - the gray wire - marked SH (shield) above, should remain grounded to the mounting bracket & in turn to the chassis.
Request a Quote Datasheet

Suppliers

Company
Product
Description
Supplier Links
Transformers - Classic Transformers - 260A6 - Hammond Manufacturing Company Inc.
Cheektowaga, NY, United States
Transformers - Classic Transformers
260A6
Transformers - Classic Transformers 260A6
Features Universal primary with taps for 100, 120, 220 or 240 VAC, 50/60 Hz. (Except the 260A6 which is 117V, 50/60 Hz only) Designed for preamps, low power amps, general replacement, test equipment, etc. Economical, open frame, chassis mount - two hole (.187 dia. = G) channel bracket (figure #1) or four hole mounting (figure #2). Units include a Faraday shield between the primary and secondary windings. Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries. Minimum 5" long leads. For more selection check out our 300 Series of universal plate & filament transformers. NOTES These units are designed to run with BOTH primary windings energized for maximum efficiency (see wiring table below). The Faraday shield lead - the gray wire - marked SH (shield) above, should remain grounded to the mounting bracket & in turn to the chassis.

Features


  • Universal primary with taps for 100, 120, 220 or 240 VAC, 50/60 Hz. (Except the 260A6 which is 117V, 50/60 Hz only)
  • Designed for preamps, low power amps, general replacement, test equipment, etc.
  • Economical, open frame, chassis mount - two hole (.187 dia. = G) channel bracket (figure #1) or four hole mounting (figure #2).
  • Units include a Faraday shield between the primary and secondary windings. Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries.
  • Minimum 5" long leads.
  • For more selection check out our 300 Series of universal plate & filament transformers.

NOTES

  1. These units are designed to run with BOTH primary windings energized for maximum efficiency (see wiring table below).
  2. The Faraday shield lead - the gray wire - marked SH (shield) above, should remain grounded to the mounting bracket & in turn to the chassis.
Supplier's Site
Transformers - 260A6 - Powell Electronics, Inc.
Swedesboro, NJ, United States
Transformers
260A6
Transformers 260A6
117V,50/60, 370-0-370,60MA

117V,50/60, 370-0-370,60MA

Buy Now
Power Transformers - HM4899-ND - DigiKey
Thief River Falls, MN, United States
Power Transformers
HM4899-ND
Power Transformers HM4899-ND
PWR XFMR CHAS MT

PWR XFMR CHAS MT

Buy Now Datasheet
Shenzhen, China
Transformers - Power Transformers
260A6
Transformers - Power Transformers 260A6
PWR XFMR CHAS MT

PWR XFMR CHAS MT

Supplier's Site

Technical Specifications

  Hammond Manufacturing Company Inc. Powell Electronics, Inc. DigiKey Acme Chip Technology Co., Limited
Product Category Transformers Transformers Power Transformers Power Transformers
Product Number 260A6 260A6 HM4899-ND 260A6
Product Name Transformers - Classic Transformers Transformers Power Transformers Transformers - Power Transformers
Category Signal Signal
Other Transformer Types / Applications Electronics; Power Transformer
Standards RoHS
Unlock Full Specs
to access all available technical data