GE's series of Multilin P30 PDCs and PMU devices leverage the latest advances in synchrophasor and computing technologies available for the power industry to enable synchrophasor based wide area monitoring applications.
Key Benefits
Reduce deployment and operation cost of wide area monitoring systems integrating more Phasor Measurement Units (PMUs) per PDC
Simplify analysis of power system events through fast and easy access to time synchronized phasor data archives
Implement NERC-PRC-002-2 (draft) compliant dynamic disturbance recording (DDR) systems
Integrate P30 PDC into NERC-CIP compliant systems using the built-in security features
Enable control system wide area monitoring applications to reveal dynamics of the power grid though low latency time aligned synchrophasor signals
Customize wide area monitoring systems with the optional Multilin P30 applications module without the costs associated with additional hardware
Applications
Collection, aggregation, archiving of synchrophasor time aligned data within the Substation for enhanced post event analysis.
Continuous recording and reporting of synchrophasor data through up to eight C37.118 clients for wide area monitoring applications
Deployment of NERC-PRC-002-2 compliant Dynamic Disturbance Recording systems
Visualization of live or recorded synchronized phasor data at substation, multiple substations and regional control centers
Multilin P30 Phasor Data Concentrator
GE's series of Multilin P30 PDCs and PMU devices leverage the latest advances in synchrophasor and computing technologies available for the power industry to enable synchrophasor based wide area monitoring applications.
Key Benefits
- Reduce deployment and operation cost of wide area
monitoring systems integrating more Phasor
Measurement Units (PMUs) per PDC
- Simplify analysis of power system events through fast
and easy access to time synchronized phasor data archives
- Implement NERC-PRC-002-2 (draft) compliant dynamic disturbance recording (DDR) systems
- Integrate P30 PDC into NERC-CIP compliant systems using the built-in security features
- Enable control system wide area monitoring applications to reveal dynamics of the power grid though low latency time aligned synchrophasor signals
- Customize wide area monitoring systems with the optional Multilin P30 applications module without the costs associated with additional hardware
Applications
- Collection, aggregation, archiving of synchrophasor time aligned data within the Substation for enhanced post event analysis.
- Continuous recording and reporting of synchrophasor data through up to eight C37.118 clients for wide area monitoring applications
- Deployment of NERC-PRC-002-2 compliant Dynamic Disturbance Recording systems
- Visualization of live or recorded synchronized phasor data at substation, multiple substations and regional control centers