FIS Inc. OralChroma™ - Breath Testing Device CHM-2

Description
Three major halitosis components are hydrogen sulfide, methyl mercaptan, and dimethyl sulfide. The OralChroma measures Volatile Sulfide Components (VSC) in the breath and separates them into the above three components. About 1000 sets of OralChroma have been supplied to dentists, universities, and laboratories in the world since 2002. Separating halitosis into three major components with high precision Since the OralChroma uses gas chromatography technology, causes of halitosis can be precisely analyzed to confirm breath odor diagnostics treatment.
Description
Three major halitosis components are hydrogen sulfide, methyl mercaptan, and dimethyl sulfide. The OralChroma measures Volatile Sulfide Components (VSC) in the breath and separates them into the above three components. About 1000 sets of OralChroma have been supplied to dentists, universities, and laboratories in the world since 2002. Separating halitosis into three major components with high precision Since the OralChroma uses gas chromatography technology, causes of halitosis can be precisely analyzed to confirm breath odor diagnostics treatment.

Suppliers

Company
Product
Description
Supplier Links
OralChroma™ - Breath Testing Device - CHM-2 - FIS Inc.
Edmonds, WA, United States
OralChroma™ - Breath Testing Device
CHM-2
OralChroma™ - Breath Testing Device CHM-2
Three major halitosis components are hydrogen sulfide, methyl mercaptan, and dimethyl sulfide. The OralChroma measures Volatile Sulfide Components (VSC) in the breath and separates them into the above three components. About 1000 sets of OralChroma have been supplied to dentists, universities, and laboratories in the world since 2002. Separating halitosis into three major components with high precision Since the OralChroma uses gas chromatography technology, causes of halitosis can be precisely analyzed to confirm breath odor diagnostics treatment.

Three major halitosis components are hydrogen sulfide, methyl mercaptan, and dimethyl sulfide. The OralChroma measures Volatile Sulfide Components (VSC) in the breath and separates them into the above three components. About 1000 sets of OralChroma have been supplied to dentists, universities, and laboratories in the world since 2002.

Separating halitosis into three major components with high precision

Since the OralChroma uses gas chromatography technology, causes of halitosis can be precisely analyzed to confirm breath odor diagnostics treatment.

Supplier's Site

Technical Specifications

  FIS Inc.
Product Category Gas Instruments
Product Number CHM-2
Product Name OralChroma™ - Breath Testing Device
Measurement Type Trace
Application Process Gas
Gas Types Toxic; H2S; (Methyl Mercaptan; Dimethyl Sulfide)
Instrument Type Analyzer
Mounting Type Portable
Unlock Full Specs
to access all available technical data

Similar Products

SC-04 Sulfur Dioxide (SO2) Portable Gas Monitor -  - DOD Technologies Inc.
Specs
Display Digital
Features Intrinsically Safe
Instrument Type Monitor
View Details
VOC Environmental Meter - PCE-VOC 1 - PCE Instruments / PCE Americas Inc.
PCE Instruments / PCE Americas Inc.
Specs
Gas Types Toxic; (Formaldehyde (HCHO))
Instrument Type Detector
Operating Temperature 32 to 104 F (0 to 40 C)
View Details
Fixed Point Gas Detector - Vanguard WirelessHART® - United Electric Controls Company
Specs
Measurement Type %LEL or %LFL; Trace
Application Process Gas
Gas Types Toxic; Combustible; NH3; (0 - 100 ppm); CO; (0 - 500 ppm); H2S; (0 - 100 ppm); Methane (CH4) / Natural Gas; (0 to 100% LEL); (Propane (C3H8) 0 to 100% LEL)
View Details
Multi Sensor Aspirated Based Monitoring System - Model SA-4XES - Safeguard Analytics
Specs
Measurement Type %LEL or %LFL; %Volume; Trace; Leakage
Application Personal Exposure Monitoring; Confined Space Entry; Continuous Emissions Monitoring; Ambient Air Monitoring
Gas Types Toxic; Combustible; (Oxygen Deficiency, VOCs, Refrigerants)
View Details