Emerson Automation Solutions – Rosemount Insertion/Submersion Conductivity Sensor Model 150

Description
IDEAL FOR USE AS A SETPOINT DETECTOR where accuracy over a broad range of conductivity is not needed SUITABLE FOR INSERTION OR SUBMERSION APPLICATIONS AVAILABLE WITH 0.1, 0.5 AND 1.0/cm CELL CONSTANTS The Model 150 contacting conductivity sensor is a good choice for applications where accuracy over a broad range of conductivity is not necessary. An example is controlling blowdown in open cooling water systems. The sensor has front and rear-facing 1-inch MNPT process connections. It can be screwed directly into a pipe tee using the front threads or can be attached using the rear threads to a pipe for submersion into a tank or vessel. The sensor is available with 0.1, 0.5, and 1.0/cm cell constants.
Datasheet
Description
IDEAL FOR USE AS A SETPOINT DETECTOR where accuracy over a broad range of conductivity is not needed SUITABLE FOR INSERTION OR SUBMERSION APPLICATIONS AVAILABLE WITH 0.1, 0.5 AND 1.0/cm CELL CONSTANTS The Model 150 contacting conductivity sensor is a good choice for applications where accuracy over a broad range of conductivity is not necessary. An example is controlling blowdown in open cooling water systems. The sensor has front and rear-facing 1-inch MNPT process connections. It can be screwed directly into a pipe tee using the front threads or can be attached using the rear threads to a pipe for submersion into a tank or vessel. The sensor is available with 0.1, 0.5, and 1.0/cm cell constants.
Datasheet

Suppliers

Company
Product
Description
Supplier Links
Insertion/Submersion Conductivity Sensor - Model 150 - Emerson Automation Solutions – Rosemount
Irvine, CA, USA
Insertion/Submersion Conductivity Sensor
Model 150
Insertion/Submersion Conductivity Sensor Model 150
IDEAL FOR USE AS A SETPOINT DETECTOR where accuracy over a broad range of conductivity is not needed SUITABLE FOR INSERTION OR SUBMERSION APPLICATIONS AVAILABLE WITH 0.1, 0.5 AND 1.0/cm CELL CONSTANTS The Model 150 contacting conductivity sensor is a good choice for applications where accuracy over a broad range of conductivity is not necessary. An example is controlling blowdown in open cooling water systems. The sensor has front and rear-facing 1-inch MNPT process connections. It can be screwed directly into a pipe tee using the front threads or can be attached using the rear threads to a pipe for submersion into a tank or vessel. The sensor is available with 0.1, 0.5, and 1.0/cm cell constants.
  • IDEAL FOR USE AS A SETPOINT DETECTOR where accuracy over a broad range of conductivity is not needed
  • SUITABLE FOR INSERTION OR SUBMERSION APPLICATIONS
  • AVAILABLE WITH 0.1, 0.5 AND 1.0/cm CELL CONSTANTS

The Model 150 contacting conductivity sensor is a good choice for applications where accuracy over a broad range of conductivity is not necessary. An example is controlling blowdown in open cooling water systems.

The sensor has front and rear-facing 1-inch MNPT process connections. It can be screwed directly into a pipe tee using the front threads or can be attached using the rear threads to a pipe for submersion into a tank or vessel.

The sensor is available with 0.1, 0.5, and 1.0/cm cell constants.

Supplier's Site Datasheet

Technical Specifications

  Emerson Automation Solutions – Rosemount
Product Category Conductivity Electrodes
Product Number Model 150
Product Name Insertion/Submersion Conductivity Sensor
Conductivity Range 0.0 to 10000 MicroSiemens/cm
Cell Constant (k) 0.1; 1; 0.5
Mounting Options In-Line (Insertion)
Maximum Diameter / Width 1 inch (25.4 mm)
Unlock Full Specs
to access all available technical data

Similar Products

750 II Conductivity/TDS Monitor/Controller - 759II - Myron L Company
Specs
Conductivity Range 0.0 to 200 MicroSiemens/cm
Electrode Accuracy 1 (+/- % FS)
Maximum Diameter / Width 4.8 inch (122 mm)
View Details
5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable 0.65 m) - 6.00925.100 - Metrohm USA, Inc.
Specs
Conductivity Range 0.0050 to 20 MicroSiemens/cm
Operating Temp 32 to 158 F (0.0 to 70 C)
View Details
Tri-clamp type, stainless steel electrodes - Model TB451 - ABB Measurement & Analytics
Specs
Conductivity Range 0.0 to 2.00E6 MicroSiemens/cm
Cell Constant (k) 0
Mounting Options In-Line (Insertion)
View Details
CONDUCELL PWSE ARC TC 1.5
Specs
Conductivity Range 0.0100 to 2000 MicroSiemens/cm
Electrode Accuracy 3 (+/- % FS)
Cell Constant (k) 0.1
View Details