Emerson Automation Solutions – Rosemount Insertion/Submersion Conductivity Sensor Model 150

Description
IDEAL FOR USE AS A SETPOINT DETECTOR where accuracy over a broad range of conductivity is not needed SUITABLE FOR INSERTION OR SUBMERSION APPLICATIONS AVAILABLE WITH 0.1, 0.5 AND 1.0/cm CELL CONSTANTS The Model 150 contacting conductivity sensor is a good choice for applications where accuracy over a broad range of conductivity is not necessary. An example is controlling blowdown in open cooling water systems. The sensor has front and rear-facing 1-inch MNPT process connections. It can be screwed directly into a pipe tee using the front threads or can be attached using the rear threads to a pipe for submersion into a tank or vessel. The sensor is available with 0.1, 0.5, and 1.0/cm cell constants.
Datasheet
Description
IDEAL FOR USE AS A SETPOINT DETECTOR where accuracy over a broad range of conductivity is not needed SUITABLE FOR INSERTION OR SUBMERSION APPLICATIONS AVAILABLE WITH 0.1, 0.5 AND 1.0/cm CELL CONSTANTS The Model 150 contacting conductivity sensor is a good choice for applications where accuracy over a broad range of conductivity is not necessary. An example is controlling blowdown in open cooling water systems. The sensor has front and rear-facing 1-inch MNPT process connections. It can be screwed directly into a pipe tee using the front threads or can be attached using the rear threads to a pipe for submersion into a tank or vessel. The sensor is available with 0.1, 0.5, and 1.0/cm cell constants.
Datasheet

Suppliers

Company
Product
Description
Supplier Links
Insertion/Submersion Conductivity Sensor - Model 150 - Emerson Automation Solutions – Rosemount
Irvine, CA, USA
Insertion/Submersion Conductivity Sensor
Model 150
Insertion/Submersion Conductivity Sensor Model 150
IDEAL FOR USE AS A SETPOINT DETECTOR where accuracy over a broad range of conductivity is not needed SUITABLE FOR INSERTION OR SUBMERSION APPLICATIONS AVAILABLE WITH 0.1, 0.5 AND 1.0/cm CELL CONSTANTS The Model 150 contacting conductivity sensor is a good choice for applications where accuracy over a broad range of conductivity is not necessary. An example is controlling blowdown in open cooling water systems. The sensor has front and rear-facing 1-inch MNPT process connections. It can be screwed directly into a pipe tee using the front threads or can be attached using the rear threads to a pipe for submersion into a tank or vessel. The sensor is available with 0.1, 0.5, and 1.0/cm cell constants.
  • IDEAL FOR USE AS A SETPOINT DETECTOR where accuracy over a broad range of conductivity is not needed
  • SUITABLE FOR INSERTION OR SUBMERSION APPLICATIONS
  • AVAILABLE WITH 0.1, 0.5 AND 1.0/cm CELL CONSTANTS

The Model 150 contacting conductivity sensor is a good choice for applications where accuracy over a broad range of conductivity is not necessary. An example is controlling blowdown in open cooling water systems.

The sensor has front and rear-facing 1-inch MNPT process connections. It can be screwed directly into a pipe tee using the front threads or can be attached using the rear threads to a pipe for submersion into a tank or vessel.

The sensor is available with 0.1, 0.5, and 1.0/cm cell constants.

Supplier's Site Datasheet

Technical Specifications

  Emerson Automation Solutions – Rosemount
Product Category Conductivity Electrodes
Product Number Model 150
Product Name Insertion/Submersion Conductivity Sensor
Conductivity Range 0.0 to 10000 MicroSiemens/cm
Cell Constant (k) 0.1; 1; 0.5
Mounting Options In-Line (Insertion)
Maximum Diameter / Width 1 inch (25.4 mm)
Unlock Full Specs
to access all available technical data

Similar Products

Flow-through type, carbon electrode - AC212 - ABB Measurement & Analytics
Specs
Conductivity Range 0.0 to 10000 MicroSiemens/cm
Cell Constant (k) 0.1; 1
Mounting Options Flow Thru (Pipeline)
View Details
Conductive conductivity sensor - LDL321 - ifm efector inc.
Specs
Conductivity Range 0.0400 to 1000 MicroSiemens/cm
Electrode Accuracy 3 (+/- % FS)
Response Time 2 seconds
View Details
Conductivity Sensors - LFS1305 - Innovative Sensor Technology IST USA Division
Innovative Sensor Technology IST USA Division
Specs
Conductivity Range 100 to 200000 MicroSiemens/cm
Cell Constant (k) 0.86 cm-1
Mounting Options In-Line (Insertion)
View Details
Conductivity measuring cell c = 0.1 cm-1 with Pt1000 (fixed cable, 2.0 m) - 6.00922.040 - Metrohm USA, Inc.
Specs
Conductivity Range 0.0100 to 1000 MicroSiemens/cm
Operating Temp 32 to 158 F (0.0 to 70 C)