DAS Environmental Expert GmbH Waste Gas Treatment Electrostatic Condensate Separator JUNIPER

Description
Electrostatic Condensate Separation with JUNIPER at the Point-Of-Use Electrostatic Condensate Separation with JUNIPER The electrostatic condensate separator JUNIPER reliably and cost-effectively removes condensable organic compounds (VOC´s) like those that accrue in manufacturing fabs in the photovoltaic industry. Many of these organic compounds have a bad odor and many of them are toxic. JUNIPER is capable of handling waste gas flows up to 1000 m3/h. Separation rates are above up to 95 %. The system prevents exhaust blockage through condensates by reducing the overall carbon content of waste gases, and in addition, separates dusts from the waste gases. Essential advantages of this system are its low energy consumption and small foot print. Access for operating and maintenance is found on the front and back sides as at most DAS tools. JUNIPER- Operating Principle With JUNIPER waste gas flows are entered quickly into the system. Hot waste gas enters a cooler and the temperature is reduced to the organic compounds’ condensation temperature. Afterwards, aerosols are channeled through separator columns, where its ionized, and condensed components are deposited on grounded metal tubes. The separated condensate flows back into the tank where it is collected. It can be pumped out automatically or drained manually. The following equipment options are available for all JUNIPER systems: Power Supply: 3 x 400 V/50 Hz or 3 x 208 V/60 Hz Condensate pump Signal Tower Drip Pan Earthquake Safety Kit
Description
Electrostatic Condensate Separation with JUNIPER at the Point-Of-Use Electrostatic Condensate Separation with JUNIPER The electrostatic condensate separator JUNIPER reliably and cost-effectively removes condensable organic compounds (VOC´s) like those that accrue in manufacturing fabs in the photovoltaic industry. Many of these organic compounds have a bad odor and many of them are toxic. JUNIPER is capable of handling waste gas flows up to 1000 m3/h. Separation rates are above up to 95 %. The system prevents exhaust blockage through condensates by reducing the overall carbon content of waste gases, and in addition, separates dusts from the waste gases. Essential advantages of this system are its low energy consumption and small foot print. Access for operating and maintenance is found on the front and back sides as at most DAS tools. JUNIPER- Operating Principle With JUNIPER waste gas flows are entered quickly into the system. Hot waste gas enters a cooler and the temperature is reduced to the organic compounds’ condensation temperature. Afterwards, aerosols are channeled through separator columns, where its ionized, and condensed components are deposited on grounded metal tubes. The separated condensate flows back into the tank where it is collected. It can be pumped out automatically or drained manually. The following equipment options are available for all JUNIPER systems: Power Supply: 3 x 400 V/50 Hz or 3 x 208 V/60 Hz Condensate pump Signal Tower Drip Pan Earthquake Safety Kit

Suppliers

Company
Product
Description
Supplier Links
Waste Gas Treatment Electrostatic Condensate Separator - JUNIPER - DAS Environmental Expert GmbH
Dresden, Germany
Waste Gas Treatment Electrostatic Condensate Separator
JUNIPER
Waste Gas Treatment Electrostatic Condensate Separator JUNIPER
Electrostatic Condensate Separation with JUNIPER at the Point-Of-Use Electrostatic Condensate Separation with JUNIPER The electrostatic condensate separator JUNIPER reliably and cost-effectively removes condensable organic compounds (VOC´s) like those that accrue in manufacturing fabs in the photovoltaic industry. Many of these organic compounds have a bad odor and many of them are toxic. JUNIPER is capable of handling waste gas flows up to 1000 m3/h. Separation rates are above up to 95 %. The system prevents exhaust blockage through condensates by reducing the overall carbon content of waste gases, and in addition, separates dusts from the waste gases. Essential advantages of this system are its low energy consumption and small foot print. Access for operating and maintenance is found on the front and back sides as at most DAS tools. JUNIPER- Operating Principle With JUNIPER waste gas flows are entered quickly into the system. Hot waste gas enters a cooler and the temperature is reduced to the organic compounds’ condensation temperature. Afterwards, aerosols are channeled through separator columns, where its ionized, and condensed components are deposited on grounded metal tubes. The separated condensate flows back into the tank where it is collected. It can be pumped out automatically or drained manually. The following equipment options are available for all JUNIPER systems: Power Supply: 3 x 400 V/50 Hz or 3 x 208 V/60 Hz Condensate pump Signal Tower Drip Pan Earthquake Safety Kit

Electrostatic Condensate Separation with JUNIPER at the Point-Of-Use

Electrostatic Condensate Separation with JUNIPER

The electrostatic condensate separator JUNIPER reliably and cost-effectively removes condensable organic compounds (VOC´s) like those that accrue in manufacturing fabs in the photovoltaic industry. Many of these organic compounds have a bad odor and many of them are toxic. JUNIPER is capable of handling waste gas flows up to 1000 m3/h. Separation rates are above up to 95 %. The system prevents exhaust blockage through condensates by reducing the overall carbon content of waste gases, and in addition, separates dusts from the waste gases. Essential advantages of this system are its low energy consumption and small foot print. Access for operating and maintenance is found on the front and back sides as at most DAS tools.

JUNIPER- Operating Principle

With JUNIPER waste gas flows are entered quickly into the system. Hot waste gas enters a cooler and the temperature is reduced to the organic compounds’ condensation temperature. Afterwards, aerosols are channeled through separator columns, where its ionized, and condensed components are deposited on grounded metal tubes. The separated condensate flows back into the tank where it is collected. It can be pumped out automatically or drained manually.

The following equipment options are available for all JUNIPER systems:

  • Power Supply: 3 x 400 V/50 Hz or 3 x 208 V/60 Hz
  • Condensate pump
  • Signal Tower
  • Drip Pan
  • Earthquake Safety Kit
Supplier's Site

Technical Specifications

  DAS Environmental Expert GmbH
Product Category Dust Collectors and Dust Collector Filters
Product Number JUNIPER
Product Name Waste Gas Treatment Electrostatic Condensate Separator
Separation / Filtration System Electrostatic Precipitators
Unlock Full Specs
to access all available technical data

Similar Products

FCC Reactor & Regenerator Cyclones -  - Ducon Environmental Systems 
Ducon Environmental Systems 
Specs
Collector Type Fluid Catalytic Cracking (FCC)
Applications Refinery Processes
Process Dry Type
View Details
Vortex And Venturi Wet Scrubber Dust Collectors -  - Camfil
Specs
Collector Type Stationary Unit
Process Dry Type
Separation / Filtration System Cyclone (Centrifugal) Separator
View Details
Amtech ADT Dust Collectors - Amtech ADT-2 - Clean Air Industries
Specs
Applications Abrasives; FinePowders; Metalworking Chips / Fluid; Welding Fumes
Airflow 1000 SCFM (1700 m³/hr)
Efficiency 99.5 %
View Details
Portable Dust Collectors -  - Cincinnati Fan
Specs
Collector Type Source Collector / Portable
Applications Abrasives; FinePowders; General Cleaning; Metalworking Chips / Fluid; Woodworking, Grinding and Buffing Machine
Process Dry Type
View Details