CSA Group Water quality - Determination of fluoride using flow analysis (FIA and CFA) - Part 1: Method using flow injection analysis (FIA) and spectrometric detection after off-line distillation ISO/TS 17951-1:2016

Description
ISO/TS 17951-1:2016 specifies a method for the determination of fluoride in waters, waste waters and effluents by flow injection analysis (FIA). Any insoluble or complexed fluoride is converted to fluoride ion by a manual distillation procedure from sulfuric/phosphoric acid. Fluoride ion in the distillate is measured using flow analysis with lanthanum alizarin complexone and spectrometric detection. This method is applicable to industrial waste waters, effluents, surface waters, ground waters, leachates. It is not recommended for drinking waters where a distillation step is not required. In ISO/TS 17951-1:2016, two working ranges are described: - working range I: 0,1 mg/l to 1 mg/l; - working range II: 1 mg/l to 10 mg/l. The specification of the calibration solutions are to be adapted accordingly.
Description
ISO/TS 17951-1:2016 specifies a method for the determination of fluoride in waters, waste waters and effluents by flow injection analysis (FIA). Any insoluble or complexed fluoride is converted to fluoride ion by a manual distillation procedure from sulfuric/phosphoric acid. Fluoride ion in the distillate is measured using flow analysis with lanthanum alizarin complexone and spectrometric detection. This method is applicable to industrial waste waters, effluents, surface waters, ground waters, leachates. It is not recommended for drinking waters where a distillation step is not required. In ISO/TS 17951-1:2016, two working ranges are described: - working range I: 0,1 mg/l to 1 mg/l; - working range II: 1 mg/l to 10 mg/l. The specification of the calibration solutions are to be adapted accordingly.

Suppliers

Company
Product
Description
Supplier Links
Water quality - Determination of fluoride using flow analysis (FIA and CFA) - Part 1: Method using flow injection analysis (FIA) and spectrometric detection after off-line distillation - ISO/TS 17951-1:2016 - CSA Group
Toronto, Ontario, Canada
Water quality - Determination of fluoride using flow analysis (FIA and CFA) - Part 1: Method using flow injection analysis (FIA) and spectrometric detection after off-line distillation
ISO/TS 17951-1:2016
Water quality - Determination of fluoride using flow analysis (FIA and CFA) - Part 1: Method using flow injection analysis (FIA) and spectrometric detection after off-line distillation ISO/TS 17951-1:2016
ISO/TS 17951-1:2016 specifies a method for the determination of fluoride in waters, waste waters and effluents by flow injection analysis (FIA). Any insoluble or complexed fluoride is converted to fluoride ion by a manual distillation procedure from sulfuric/phosphoric acid. Fluoride ion in the distillate is measured using flow analysis with lanthanum alizarin complexone and spectrometric detection. This method is applicable to industrial waste waters, effluents, surface waters, ground waters, leachates. It is not recommended for drinking waters where a distillation step is not required. In ISO/TS 17951-1:2016, two working ranges are described: - working range I: 0,1 mg/l to 1 mg/l; - working range II: 1 mg/l to 10 mg/l. The specification of the calibration solutions are to be adapted accordingly.

ISO/TS 17951-1:2016 specifies a method for the determination of fluoride in waters, waste waters and effluents by flow injection analysis (FIA). Any insoluble or complexed fluoride is converted to fluoride ion by a manual distillation procedure from sulfuric/phosphoric acid. Fluoride ion in the distillate is measured using flow analysis with lanthanum alizarin complexone and spectrometric detection. This method is applicable to industrial waste waters, effluents, surface waters, ground waters, leachates. It is not recommended for drinking waters where a distillation step is not required. In ISO/TS 17951-1:2016, two working ranges are described:

- working range I: 0,1 mg/l to 1 mg/l;

- working range II: 1 mg/l to 10 mg/l.

The specification of the calibration solutions are to be adapted accordingly.