CSA Group Water quality - Determination of permanganate index ISO 8467:1993

Description
The principle of the method specified is heating a sample in a boiling water-bath with a known amount of potassium permanganate und sulfuric acid for a fixed period time (10 min), reducing part of the permanganate by oxidizable material in the sample and determining the consumed permanganate by addition of an excess of oxalate solution, followed by titration with permanganate. Applies to waters having a cloride ion concentration of less than 300 mg/l. Samples having a permanganate index over 10 mg/l should be diluted before analysis. The lower limit of the optimum range of the test is 0,5 mg/l.
Description
The principle of the method specified is heating a sample in a boiling water-bath with a known amount of potassium permanganate und sulfuric acid for a fixed period time (10 min), reducing part of the permanganate by oxidizable material in the sample and determining the consumed permanganate by addition of an excess of oxalate solution, followed by titration with permanganate. Applies to waters having a cloride ion concentration of less than 300 mg/l. Samples having a permanganate index over 10 mg/l should be diluted before analysis. The lower limit of the optimum range of the test is 0,5 mg/l.

Suppliers

Company
Product
Description
Supplier Links
Water quality - Determination of permanganate index - ISO 8467:1993 - CSA Group
Toronto, Ontario, Canada
Water quality - Determination of permanganate index
ISO 8467:1993
Water quality - Determination of permanganate index ISO 8467:1993
The principle of the method specified is heating a sample in a boiling water-bath with a known amount of potassium permanganate und sulfuric acid for a fixed period time (10 min), reducing part of the permanganate by oxidizable material in the sample and determining the consumed permanganate by addition of an excess of oxalate solution, followed by titration with permanganate. Applies to waters having a cloride ion concentration of less than 300 mg/l. Samples having a permanganate index over 10 mg/l should be diluted before analysis. The lower limit of the optimum range of the test is 0,5 mg/l.

The principle of the method specified is heating a sample in a boiling water-bath with a known amount of potassium permanganate und sulfuric acid for a fixed period time (10 min), reducing part of the permanganate by oxidizable material in the sample and determining the consumed permanganate by addition of an excess of oxalate solution, followed by titration with permanganate. Applies to waters having a cloride ion concentration of less than 300 mg/l. Samples having a permanganate index over 10 mg/l should be diluted before analysis. The lower limit of the optimum range of the test is 0,5 mg/l.

Supplier's Site

Technical Specifications

  CSA Group
Product Category Standards and Technical Documents
Product Number ISO 8467:1993
Product Name Water quality - Determination of permanganate index
Unlock Full Specs
to access all available technical data

Similar Products